Warranty and Assistance 

The

 

SDM-CD16D 16 CHANNEL DIGITAL CONTROL PORT 

EXPANSION MODULE 

is warranted by CAMPBELL SCIENTIFIC, INC. to 

be free from defects in materials and workmanship under normal use and 
service for twelve (12) months from date of shipment unless specified 
otherwise.  Batteries have no warranty.  CAMPBELL SCIENTIFIC, INC.'s 
obligation under this warranty is limited to repairing or replacing (at 
CAMPBELL SCIENTIFIC, INC.'s option) defective products.  The customer 
shall assume all costs of removing, reinstalling, and shipping defective 
products to CAMPBELL SCIENTIFIC, INC.  CAMPBELL SCIENTIFIC, 
INC. will return such products by surface carrier prepaid.  This warranty shall 
not apply to any CAMPBELL SCIENTIFIC, INC. products which have been 
subjected to modification, misuse, neglect, accidents of nature, or shipping 
damage.  This warranty is in lieu of all other warranties, expressed or implied, 
including warranties of merchantability or fitness for a particular purpose.  
CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, 
or consequential damages. 

Products may not be returned without prior authorization.  The following 
contact information is for US and International customers residing in countries 
served by Campbell Scientific, Inc. directly.  Affiliate companies handle 
repairs for customers within their territories.  Please visit 
www.campbellsci.com to determine which Campbell Scientific company 
serves your country.  To obtain a Returned Materials Authorization (RMA), 
contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342.  After an 
applications engineer determines the nature of the problem, an RMA number 
will be issued.  Please write this number clearly on the outside of the shipping 
container.  CAMPBELL SCIENTIFIC's shipping address is: 

 

 

CAMPBELL SCIENTIFIC, INC. 

 RMA#_____ 
 

815 West 1800 North 

 

Logan, Utah 84321-1784 

 

CAMPBELL SCIENTIFIC, INC. does not accept collect calls. 

 

 

 

Summary of Contents for SDM-CD16D

Page 1: ...SDM CD16D 16 Channel Digital Control Port Expansion Module Revision 8 07 C o p y r i g h t 2 0 0 0 2 0 0 7 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ...in lieu of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental o...

Page 3: ...Considerations 3 4 Installation 4 4 1 Controlled Device Connections 4 5 Address Selection Switches 5 6 Datalogger Instructions 7 6 1 CRBasic 7 6 2 Edlog 7 7 Theory of Operation 8 8 Program Examples 8...

Page 4: ...This is a blank page...

Page 5: ...ct control of low voltage valves relays etc The SDM CD16D is a synchronously addressed datalogger peripheral Three ports on the datalogger are used to address the SDM CD16D then clock out the desired...

Page 6: ...t Source Current Output will source 36 mA 3 V 115 mA short circuited to ground Max Output Current 400 mA at 50 C and 12 V supply see NOTE below total all outputs The maximum current should be derated...

Page 7: ...Alkaline batteries are not recommended for long term applications Connection with External Supply Connection with Datalogger Supply GND EXTERNAL 9 TO 18V DC SDM CD16D DATALOGGER 12V C1 C2 C3 SDM C1 o...

Page 8: ...corner of the 700X control module NOTE Multiple SDM CD16Ds may be wired in parallel by connecting the datalogger side of one SDM CD16D to the next The transient protection of the SDM CD16D relies on...

Page 9: ...han one solid core wire into one terminal connector unless the wires are soldered or clamped together When inserting more than one stranded wire twist the bare ends together before insertion NOTE Use...

Page 10: ...rt Expansion Module TABLE 2 Switch Position and Addresses Switch Setting Base 4 Address 0 00 1 01 2 02 3 03 4 10 5 11 6 12 7 13 8 20 9 21 A 22 B 23 C 30 D 31 E 32 F 33 Use a screwdriver to select addr...

Page 11: ...imes the number of Repetitions the number of SDM CD16D devices to be controlled As an example with the array CDCtrl 32 the value held in CDCtrl 1 will be sent to port 1 the value held in CDCtrl 2 will...

Page 12: ...pecified in parameter 3 parameter 5 for Instruction 29 Any non zero value stored in an input location activates sets HI 5 V the associated SDM CD16D port A value of zero 0 de activates the port sets L...

Page 13: ...following CR1000 program example a counter is used to fill an array called Src that will control two SDM CD16Ds Dimension Variables Public src 32 Dim i count mask 16 Program BeginProg for i 1 to 16 m...

Page 14: ...atalogger manual Input location assignments are as follows Input Input Location Location Label Description 1 5 Temp 1 5 Avg temp greenhouse 1 5 10 14 Heat 1 5 Heater control greenhouse 1 5 SDM CD16D P...

Page 15: ...location 3 10 Z Loc Heat_1 8 End P95 end then do 9 Else P94 else if the heater is off 10 Z F P30 enter a 0 into heater 1 0 F control location 2 0 Exponent of 10 3 10 Z Loc Heat_1 11 End P95 end then...

Page 16: ...0 Exponent of 10 3 15 Z Loc Cool_1 21 End P95 end then do else End cooler control logic Start fan control logic based on heater cooler 22 If X F P89 if heater is on 1 10 X Loc Heat_1 2 2 3 0 F 4 11 S...

Page 17: ...High 2 30 Then Do then 33 Beginning of Loop P87 start fan loop 1 0 Delay 2 5 Loop Count 34 Z F P30 put a 1 into fan control 1 1 F location 2 0 Exponent of 10 3 20 Z Loc Fan_1 35 End P95 end fan loop...

Page 18: ...0 7 _________ 0 0 0 8 _________ 0 0 0 9 _________ 0 0 0 10 Heat_1 7 3 3 11 Heat_2 11 1 0 12 Heat_3 11 1 0 13 Heat_4 11 1 0 14 Heat_5 19 1 0 15 Cool_1 7 3 3 16 Cool_2 11 1 0 17 Cool_3 11 1 0 18 Cool_4...

Page 19: ...This is a blank page...