RF401A-Series Spread Spectrum Radio
2
3. Initial Inspection
•
The RF401A-series radios ship with an SC12 serial cable, a USB A to
USB B Cable, 2 grommets, and 2 screws.
•
Upon receipt of the RF401A-series radio, inspect the packaging and
contents for damage. File damage claims with the shipping company.
Contact Campbell Scientific to facilitate repair or replacement.
•
Immediately check package contents against shipping documentation.
Thoroughly check all packaging material for product that may be trapped
inside it. Contact Campbell Scientific immediately about any
discrepancies. Model numbers are found on each product. On cables, the
model number is often found at the connection end of the cable.
4. QuickStart
Out of the box, the radio is configured for use with a datalogger connecting via
CS I/O and using CS I/O SDC address 7.
4.1 Remote Station Radio
Using the supplied SC12 serial cable, connect the radio’s CS I/O port to the CS
I/O port of the datalogger.
4.2 Base Station Radio
You will need to connect the radio to your PC and use
Device Configuration
Utility
to change the radio’s
Active Interface
to
USB
. To learn more about
connecting with
Device Configuration Utility
see Section
(p. 11)
. Using
Device Configuration Utility
, set the radio’s
Active Interface
setting to
USB
. If using the base radio to connect to a CR200
series, you will also need to change the
Power Mode
setting to
1 Sec
. The
Power Mode
setting should match that of the device you are connecting to.
Apply
the change(s), close
Device Configuration Utility
, and leave the radio
connected to the PC via USB.
4.3 LoggerNet Setup
The next step is to run
LoggerNet
and configure it to connect to the datalogger
via the radio link.
•
From the EZ View of the
LoggerNet Setup
screen, press
Add
, select
your datalogger type, enter a name for your datalogger, and press
Next
.
•
Under
Connection Type
, select
Direct Connect
. Press
Next
.
•
Under
COM Port Selection
, select the port designated as
RF401A-
Series
.
•
Under
Datalogger Settings
, select a
Baud Rate
of
115200
, enter the
PakBus Address
of the datalogger, and set
Extra Response Time
to
1 second
. Press
Next
.
•
Under
Datalogger Settings – Security
, enter any security codes that
have been previously configured in the datalogger, if any. Press
Next
.
•
Review the
Communication Setup Summary
and verify that all
settings are correct. Press
Next
.
Summary of Contents for RF401A Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 12: ...Table of Contents iv ...
Page 17: ...RF401A Series Spread Spectrum Radio 5 FIGURE 6 1 RF401A series dimensions ...
Page 40: ......
Page 50: ...Appendix B Distance vs Antenna Gain Terrain and Other Factors B 10 ...
Page 51: ......