Raven100 CDMA AirLink Cellular Modem
FIGURE 7-1. Device Port Configuration
b.
Try adding a few seconds to the extra response time on the IP Port in
LoggerNet (you should not need more than 5 seconds).
c.
If you are trying to communicate to a PakBus datalogger:
i.
Verify the PakBus address in the setup screen matches that of the
datalogger.
ii.
If you have multiple PakBus networks/ports setup in LoggerNet,
uncheck the ‘PakBus Port Always Open’ options on all PakBus
ports.
3. See if the modem has incoming and outgoing serial data. You can do this
by using AirLink’s Wireless Ace. Connect to the modem, and then once
you have the settings, go to the ‘Status’ link and note the serial in and
serial out values (see Figure 7-2). Now try to connect to the modem with
LoggerNet. If you don’t connect in LoggerNet, go back to Wireless Ace
and reconnect to the modem to get the settings again. Go to the ‘status’
link and compare the serial in and serial out values to those you
previously obtained.
a.
If they are still the same, the modem is not attempting to make a
connection to the datalogger (check the settings in the modem,
20