Campbell OXYGUARD TYPE III CS512 Instruction Manual Download Page 2

Warranty and Assistance 

The

 

CS512 OXYGUARD TYPE III DISSOLVED OXYGEN PROBE 

is 

warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in 
materials and workmanship under normal use and service for twelve (12) 
months from date of shipment unless specified otherwise.  Batteries have no 
warranty.  CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is 
limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) 
defective products.  The customer shall assume all costs of removing, 
reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, 
INC.  CAMPBELL SCIENTIFIC, INC. will return such products by surface 
carrier prepaid.  This warranty shall not apply to any CAMPBELL 
SCIENTIFIC, INC. products which have been subjected to modification, 
misuse, neglect, accidents of nature, or shipping damage.  This warranty is in 
lieu of all other warranties, expressed or implied, including warranties of 
merchantability or fitness for a particular purpose.  CAMPBELL SCIENTIFIC, 
INC. is not liable for special, indirect, incidental, or consequential damages. 

Products may not be returned without prior authorization.  The following 
contact information is for US and International customers residing in countries 
served by Campbell Scientific, Inc. directly.  Affiliate companies handle 
repairs for customers within their territories.  Please visit 
www.campbellsci.com to determine which Campbell Scientific company 
serves your country.  To obtain a Returned Materials Authorization (RMA), 
contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342.  After an 
applications engineer determines the nature of the problem, an RMA number 
will be issued.  Please write this number clearly on the outside of the shipping 
container.  CAMPBELL SCIENTIFIC's shipping address is: 

 

 

CAMPBELL SCIENTIFIC, INC. 

 RMA#_____ 
 

815 West 1800 North 

 

Logan, Utah 84321-1784 

 

CAMPBELL SCIENTIFIC, INC. does not accept collect calls. 

 

 

 

Summary of Contents for OXYGUARD TYPE III CS512

Page 1: ...Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision 12 06 C o p y r i g h t 2 0 0 1 2 0 0 6 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ...u of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or cons...

Page 3: ...formation 1 2 Specifications 2 3 Optional Probe Accessories 3 4 Optional Agitator 3 5 Application Information 4 6 Wiring 4 7 Programming 5 8 Calibration 6 9 Maintenance 7 10 Agitator Control 7 Appendi...

Page 4: ...P2 5 3 Sample Program using VoltSE 5 4 Sample Program using VoltDiff 5 5 Sample Program using VoltSE 5 6 Sample Program using P36 6 7 Sample Program using Expression 6 8 Sample Program using P86 and...

Page 5: ...the probe produces a millivolt output proportional to the oxygen present in the medium in which it is placed The probe consists of two parts an upper part with cathode anode and cable and a lower par...

Page 6: ...rin Membrane O ring Buna N Body Seal O ring Viton 0 05 mm 2 mil Teflon Dimensions and Weight 2 28 diameter x 2 3 height 15 9 oz Cable standard length 7 m 23 ft other lengths available upon request 2 w...

Page 7: ...es the water also has a high bio loading and the probes become fouled resulting in inaccurate DO measurements FIGURE 4 1 Preventing Bio fouling of the CS512 The PT4 Agitator overcomes these problems T...

Page 8: ...plication Information SCWin users This manual was written primarily for those whose needs are not met by SCWin Your procedure is much simpler just add the CS512 probe it s in the water folder save you...

Page 9: ...60 Hz Rejection Range code 23 used for CR23X 3 1 SE Channel 4 1 Loc DOmV 5 1 0 Multiplier See Calibration 6 0 0 Offset EXAMPLE 2 Sample Program using P2 1 Volt Diff P2 1 1 Reps 2 24 250 mV 60 Hz Reje...

Page 10: ...ing a multiplier of one 6 Change the multiplier in the datalogger program from one to the calculated number A more common way to enter the multiplier is to insert a separate instruction in the program...

Page 11: ...peat cycle timer requires no datalogger programming However some users choose to use a solid state relay and have the datalogger agitate the water on the probe face either periodically throughout the...

Page 12: ...et instruction EXAMPLE 9 Sample Program using Portset Portset 1 1 Delay 500 msec Portset 1 0 In the CR1000 CR800 CR850 and CR3000 dataloggers use the Portset instruction EXAMPLE 10 Sample Program usin...

Page 13: ...A 1 Appendix A Dissolved Oxygen in Fresh Water Table...

Page 14: ...Appendix A Dissolved Oxygen in Fresh Water Table A 2...

Page 15: ...This is a blank page...

Page 16: ...campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientif...

Reviews: