Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 

9.  Maintenance 

The CS512 probe needs little maintenance.  Regular cleaning of the membrane is 
all that is required.  The membrane is very durable and can be cleaned with a cloth 
or soft paper.  Do not scratch it clean with your fingernail.  

10.  Agitator Control 

In low flow conditions (less than about 5 cm/sec), it may be necessary to add 
an agitator to the CS512 probe.  Campbell Scientific ships the agitator with a 
repeat cycle timer.  Using the repeat cycle timer requires no datalogger 
programming.  However, some users choose to use a solid state relay and have 
the datalogger agitate the water on the probe face either periodically 
throughout the day or just before measurement.  Agitating just before the 
measurement saves on power and causes less wear and tear on the agitator and 
probe membrane. 

The wiring for the agitator as controlled by this example program would be as 
follows: 

WHITE

BLACK

Agitator

 

+                                   -

12 V Battery

4                                      1

#7321 Relay

Crydom D1D07

3                                      2

Ground/G

Datalogger

Port C1

 

FIGURE 10-1.  Agitator Wiring 

The following instructions would trigger the agitator as discussed in the 
agitator manual.  

In the CR510, CR10X, and CR23X, use instruction P86 and P22. 

Summary of Contents for OXYGUARD TYPE III CS512

Page 1: ...Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision 12 06 C o p y r i g h t 2 0 0 1 2 0 0 6 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ...u of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or cons...

Page 3: ...formation 1 2 Specifications 2 3 Optional Probe Accessories 3 4 Optional Agitator 3 5 Application Information 4 6 Wiring 4 7 Programming 5 8 Calibration 6 9 Maintenance 7 10 Agitator Control 7 Appendi...

Page 4: ...P2 5 3 Sample Program using VoltSE 5 4 Sample Program using VoltDiff 5 5 Sample Program using VoltSE 5 6 Sample Program using P36 6 7 Sample Program using Expression 6 8 Sample Program using P86 and...

Page 5: ...the probe produces a millivolt output proportional to the oxygen present in the medium in which it is placed The probe consists of two parts an upper part with cathode anode and cable and a lower par...

Page 6: ...rin Membrane O ring Buna N Body Seal O ring Viton 0 05 mm 2 mil Teflon Dimensions and Weight 2 28 diameter x 2 3 height 15 9 oz Cable standard length 7 m 23 ft other lengths available upon request 2 w...

Page 7: ...es the water also has a high bio loading and the probes become fouled resulting in inaccurate DO measurements FIGURE 4 1 Preventing Bio fouling of the CS512 The PT4 Agitator overcomes these problems T...

Page 8: ...plication Information SCWin users This manual was written primarily for those whose needs are not met by SCWin Your procedure is much simpler just add the CS512 probe it s in the water folder save you...

Page 9: ...60 Hz Rejection Range code 23 used for CR23X 3 1 SE Channel 4 1 Loc DOmV 5 1 0 Multiplier See Calibration 6 0 0 Offset EXAMPLE 2 Sample Program using P2 1 Volt Diff P2 1 1 Reps 2 24 250 mV 60 Hz Reje...

Page 10: ...ing a multiplier of one 6 Change the multiplier in the datalogger program from one to the calculated number A more common way to enter the multiplier is to insert a separate instruction in the program...

Page 11: ...peat cycle timer requires no datalogger programming However some users choose to use a solid state relay and have the datalogger agitate the water on the probe face either periodically throughout the...

Page 12: ...et instruction EXAMPLE 9 Sample Program using Portset Portset 1 1 Delay 500 msec Portset 1 0 In the CR1000 CR800 CR850 and CR3000 dataloggers use the Portset instruction EXAMPLE 10 Sample Program usin...

Page 13: ...A 1 Appendix A Dissolved Oxygen in Fresh Water Table...

Page 14: ...Appendix A Dissolved Oxygen in Fresh Water Table A 2...

Page 15: ...This is a blank page...

Page 16: ...campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientif...

Reviews: