I-1
INTRODUCTION
This manual covers both the NW8002AC (115 VAC power only) and the NW8002SP (solar panel)
weather stations. These weather stations are setup to communicate with the NW8000 central computer
over a short haul modem link. The heart of the weather station is the Campbell Scientific, Inc. CR10
Measurement and Control Module. A 2.5 amp hour 12 VDC sealed lead acid battery pack powers the
CR10. A solar panel or 115 VAC power is used to trickle charge the batteries.
SPECIFICATIONS
Power
12 VDC/115 VAC, 60 Hz
Avg. current drain
.16 A (115 VAC)
6 mA (solar panel)
Operating
temperature range -25
°
C to +50
°
C
Operating relative
humidity range
0 to 100% non-condensing
SENSOR SPECIFICATIONS
Temperature
Range
-35
°
C to +48
°
C
Accuracy
±
4
°
C, typically better than ±2
°
C
Relative Humidity
Range
12 - 97% RH
Accuracy
±5%
Wind Speed
Range
0 - 112 mph
Threshold
1.1 mph
Wind Direction
Range
0 - 112 mph
Threshold
1.8 mph
Accuracy
+5
°
Rain
Orifice
6"
Accuracy
1% at 2"/hr or less
Resolution
0.01 inches
Global Radiation
Linearity
1% up to 3000 Wm
-2
Accuracy
±5% maximum, typically ±3%
NOTE: The black outer jacket of the cables
is Santoprene
®
rubber. This compound was
chosen for its resistance to temperature
extremes, moisture, and UV degradation.
However, this jacket will support
combustion in air. It is rated as slow
burning when tested according to U.L. 94
H.B. and will pass FMVSS302. Local fire
codes may preclude its use inside buildings.
Summary of Contents for NW8002