Instruction Manual
5
PulseCount
(RMY05106WS,1,16,0,1,0.098,0.0)
PulseCount
(RMY05305WS,1,17,0,1,0.1024,0.0)
PulseCount
(RMY03101WS,1,18,0,1,0.750,0.20)
If RMY03101WS < 0.21 Then
RMY03101WS
=
0.0
EndIf
CallTable
WindSpd
NextScan
EndProg
CR5000 Example Program
'CR5000 Series Datalogger
Public Pulse_LLAC(2)
BeginProg
Scan
(1,Sec,0,0)
'Measure low level AC signal (RMY 05103) on LLAC4 wired to C7 and C8 on CR5000
TimerIO
(Pulse_LLAC,11000000,88000000,10,mSec)
'NOTE: Only ports CR5000 C7 and C8
'support Function 8 (frequency in Hz).
NextScan
EndProg
CR200(X) Example Program
'CR200(X) Series Datalogger
'LLAC4 Sample Program
'Record 10-minute average wind speed in m/s for:
'1 RM Young 05103-L Wind Monitor Anemometer
'1 RM Young 05106-L Marine Wind Monitor Anemometer
'1 RM Young 05305-L AQ Wind Monitor Anemometer
'1 RM Young 03101-L Wind Sentry Anemometer
'Declare Public Variables
Public RMY05103WS
Public RMY05106WS
Public RMY05305WS
Public RMY03101WS
'Define Data Tables
DataTable (WindSpd,1,-1)
DataInterval (0,10,min)
Average
(1,RMY05103WS,False)
Average
(1,RMY05106WS,False)
Average
(1,RMY05305WS,False)
Average
(1,RMY03101WS,False)
EndTable
'Main Program
BeginProg
Scan (1,Sec)
PulseCount
(RMY05103WS,P_LL,0,1,0.098,0.0)
PulseCount
(RMY05106WS,C1,0,1,0.098,0.0)
PulseCount
(RMY05305WS,C2,0,1,0.1024,0.0)
PulseCount
(RMY03101WS,P_SW,0,1,0.750,0.20)
If RMY03101WS < 0.21 Then