background image

Warranty and Assistance 

The

 

HUB-SDM8 

is warranted by CAMPBELL SCIENTIFIC, INC. to be free 

from defects in materials and workmanship under normal use and service for 
twelve (12) months from date of shipment unless specified otherwise.  
Batteries have no warranty.  CAMPBELL SCIENTIFIC, INC.'s obligation 
under this warranty is limited to repairing or replacing (at CAMPBELL 
SCIENTIFIC, INC.'s option) defective products.  The customer shall assume 
all costs of removing, reinstalling, and shipping defective products to 
CAMPBELL SCIENTIFIC, INC.  CAMPBELL SCIENTIFIC, INC. will 
return such products by surface carrier prepaid.  This warranty shall not apply 
to any CAMPBELL SCIENTIFIC, INC. products which have been subjected 
to modification, misuse, neglect, accidents of nature, or shipping damage.  This 
warranty is in lieu of all other warranties, expressed or implied, including 
warranties of merchantability or fitness for a particular purpose.  CAMPBELL 
SCIENTIFIC, INC. is not liable for special, indirect, incidental, or 
consequential damages. 

Products may not be returned without prior authorization.  The following 
contact information is for US and International customers residing in countries 
served by Campbell Scientific, Inc. directly.  Affiliate companies handle 
repairs for customers within their territories.  Please visit 
www.campbellsci.com to determine which Campbell Scientific company 
serves your country.  To obtain a Returned Materials Authorization (RMA), 
contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342.  After an 
applications engineer determines the nature of the problem, an RMA number 
will be issued.  Please write this number clearly on the outside of the shipping 
container.  CAMPBELL SCIENTIFIC's shipping address is: 

 

 

CAMPBELL SCIENTIFIC, INC. 

 RMA#_____ 
 

815 West 1800 North 

 

Logan, Utah 84321-1784 

 

CAMPBELL SCIENTIFIC, INC. does not accept collect calls. 

 

 

 

Summary of Contents for HUB-SDM8

Page 1: ...HUB SDM8 1 08 C o p y r i g h t 2 0 0 4 2 0 0 8 C a m p b e l l S c i e n t i f i c I n c ...

Page 2: ...ranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc directly Affili...

Page 3: ...kmarks tab for links to specific sections 1 Introduction 1 2 HUB SDM8 Specifications 1 3 General 1 4 Installation and Wiring 2 4 1 Wiring SDM Devices and Power Wires for Daisy Chain 2 5 HUB SDM5 3 6 Generic Junction Box 3 7 Maintenance 4 Figures 1 HUB SDM8 in a Daisy Chain Network 2 2 HUB SDM8 in a Daisy Chain Network Bottom View 3 i ...

Page 4: ...This is a blank page ...

Page 5: ... Terminal Strips Three spring loaded guillotine connections per terminal two terminals in common through a jumper creates eight banks Operating Temperature 55 C to 85 C Operating Humidity Noncondensing 0 95 Dimensions Length 17 8 cm 7 0 Width 19 7 cm 7 75 Depth 13 3 cm 5 25 Weight 0 88 kg 1 95 lbs 3 General Inside the HUB SDM8 enclosure are eight pairs of spring loaded guillotine terminal strips w...

Page 6: ...UB SDM8 the guillotine release slot is located to the left of the wire port Once the screwdriver has been completely inserted and has bottomed out firmly press the screwdriver down until the guillotine snaps open Insert and hold the wire as the screwdriver is removed 4 1 Wiring SDM Devices and Power Wires for Daisy Chain Before connecting the cable to the terminals strip the wire insulation back t...

Page 7: ...ngs to use the HUB SDM8 to connect multiple SDM devices to a single Campbell Scientific Inc datalogger Please refer to the HUB SDM5 manual for connecting multiple SDM devices to a datalogger using the HUB SDM8 6 Generic Junction Box The HUB SDM8 can be used as a generic junction box In its default configuration six eight conductor cables can be connected to each other Three sixteen conductor cable...

Page 8: ...HUB SDM8 4 7 Maintenance There are no user serviceable parts in the HUB SDM8 Make sure that all unused bulkhead fittings are sealed with a plug and that the lid is tightly fastened ...

Page 9: ...This is a blank page ...

Page 10: ...ZIL www campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 ru...

Reviews: