background image

HUB-SDM8 

4.  Installation and Wiring 

A U-bolt is used to mount the HUB-SDM8 to a 1.25 inch NPT pipe. 

The spring-loaded guillotines are opened with a small flat blade (2.5 x 50 mm) 
screwdriver (p/n 8125).  Orient the screwdriver blade so that the blade edge is 
perpendicular to the orange separators.  Gently insert the small flat blade 
screwdriver into the square slot located next to the circular wire port until it 
bottoms out.  For the cluster of four wire ports located on the left hand side of 
the HUB-SDM8, the guillotine release slot is located to the right of the wire 
port.  For the wire ports on the right hand side of the HUB-SDM8, the 
guillotine release slot is located to the left of the wire port.  Once the 
screwdriver has been completely inserted and has bottomed out, firmly press 
the screwdriver down until the guillotine snaps open.  Insert and hold the wire 
as the screwdriver is removed. 

4.1  Wiring SDM Devices and Power Wires for Daisy-Chain 

Before connecting the cable to the terminals, strip the wire insulation back to 
expose 1/4 inch of bare wire.  Feed the cable through the bulkhead fitting.  
Neatly separate the wires, and connect them, using the technique described in 
section 4 above.  The figures below show how two SDM devices (CSAT3 and 
LI-7500) and their power wires are connected within a daisy-chain network. 

 

SDM In

FIGURE 1.  HUB-SDM8 in a Daisy-Chain Network 

CSAT3 SDM

CSAT3 Power

LI-7500 SDM

LI-7500 Power

Power In

SDM Out

Power Out

Summary of Contents for HUB-SDM8

Page 1: ...HUB SDM8 1 08 C o p y r i g h t 2 0 0 4 2 0 0 8 C a m p b e l l S c i e n t i f i c I n c ...

Page 2: ...ranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc directly Affili...

Page 3: ...kmarks tab for links to specific sections 1 Introduction 1 2 HUB SDM8 Specifications 1 3 General 1 4 Installation and Wiring 2 4 1 Wiring SDM Devices and Power Wires for Daisy Chain 2 5 HUB SDM5 3 6 Generic Junction Box 3 7 Maintenance 4 Figures 1 HUB SDM8 in a Daisy Chain Network 2 2 HUB SDM8 in a Daisy Chain Network Bottom View 3 i ...

Page 4: ...This is a blank page ...

Page 5: ... Terminal Strips Three spring loaded guillotine connections per terminal two terminals in common through a jumper creates eight banks Operating Temperature 55 C to 85 C Operating Humidity Noncondensing 0 95 Dimensions Length 17 8 cm 7 0 Width 19 7 cm 7 75 Depth 13 3 cm 5 25 Weight 0 88 kg 1 95 lbs 3 General Inside the HUB SDM8 enclosure are eight pairs of spring loaded guillotine terminal strips w...

Page 6: ...UB SDM8 the guillotine release slot is located to the left of the wire port Once the screwdriver has been completely inserted and has bottomed out firmly press the screwdriver down until the guillotine snaps open Insert and hold the wire as the screwdriver is removed 4 1 Wiring SDM Devices and Power Wires for Daisy Chain Before connecting the cable to the terminals strip the wire insulation back t...

Page 7: ...ngs to use the HUB SDM8 to connect multiple SDM devices to a single Campbell Scientific Inc datalogger Please refer to the HUB SDM5 manual for connecting multiple SDM devices to a datalogger using the HUB SDM8 6 Generic Junction Box The HUB SDM8 can be used as a generic junction box In its default configuration six eight conductor cables can be connected to each other Three sixteen conductor cable...

Page 8: ...HUB SDM8 4 7 Maintenance There are no user serviceable parts in the HUB SDM8 Make sure that all unused bulkhead fittings are sealed with a plug and that the lid is tightly fastened ...

Page 9: ...This is a blank page ...

Page 10: ...ZIL www campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 ru...