ET107 Weather Station
21
9.
Plug the cable into the mating connector on the sensor. Plug must be fully
seated and locking ring turned fully clockwise.
10.
Install the wind vane using the Allen wrench supplied with the vane. Wind
vane should be perpendicular to the crossarm.
11.
Put the MetOne sticker over the wind vane Allen screw opening.
12.
Remove and keep the shoulder screw. The shoulder screw will be needed
for replacing bearings and/or potentiometer. The wind vane and cups
should turn freely.
13.
Plug the cable into the
WS/WD
connector on the enclosure. Ensure that
the plug is completely seated on the connector and the locking ring is
turned a quarter revolution clockwise.
Plugging this sensor into the SDI 12 connector can
damage this sensor, the main enclosure connector
board, or both.
5.5.5 WindSonic 2-D Ultrasonic Wind Sensor (Wind Sensor Option –GW)
When the WindSonic1-ET is added to the ET107, a jumper setting must be
(p. 21)
).
Jumper is set at the factory if the WindSonic is ordered with the
ET107 station.
5.5.5.1 Changing the Jumper
The procedure to change the jumper follows:
1.
Remove the cover of the enclosure.
2.
Disconnect the ribbon cable from the CS I/O port.
3.
Use a Philips screwdriver to loosen the four screws (FIGURE
).
WARNING
NOTE