![Campbell ET106 Instruction Manual Download Page 46](http://html1.mh-extra.com/html/campbell/et106/et106_instruction-manual_3804389046.webp)
Section 6. Maintenance and Troubleshooting
6-2
6.1.3 Desiccant
Enclosure humidity is monitored in the ET Enclosure and MetData1 systems by
an RH chip incorporated into the connector board. Change the desiccant packs
when the enclosure RH exceeds 35%. The RH chip should be changed every 3
to 5 years.
In standard weather stations, a humidity indicator card is provided with the
enclosure. A small RH sensor (10162) can be purchased separately to record
the RH inside the enclosure. Change the desiccant when either the card or the
sensor read about 35% RH.
Desiccant may be ordered through Campbell Scientific (DSC 20/4).
Desiccant packs inside of the dataloggers do not require replacement under
normal conditions.
6.1.4 Sensor Maintenance
Sensor maintenance should be performed at regular intervals, depending on the
desired accuracy and the conditions of use. A suggested maintenance schedule is
outlined below.
1 week
•
Check the pyranometer for level and contamination. Gently clean, if
needed.
•
Visually inspect the wind sensors and radiation shield.
1 month
•
Check the rain gage funnel for debris and level.
•
Do a visual/audio inspection of the anemometer at low wind speeds.
•
Check the filter of the temperature/humidity sensor for contamination.
General Maintenance
•
An occasional cleaning of the glass on the solar panel will improve its
efficiency.
•
Check sensor leads and cables for cracking, deterioration, proper routing,
and strain relief.
•
Check the tripod or tower for structural damage, proper alignment, and for
level/plumb.
6 months
•
Clean the temperature/humidity sensor.
•
Clean the Gill Radiation Shield.
Summary of Contents for ET106
Page 4: ...This is a blank page...
Page 20: ...Section 2 ET Tower Installation 2 6 This is a blank page...
Page 34: ...Section 3 ET Instrumentation Installation 3 14 This is a blank page...
Page 44: ...Section 5 ET Software Installation 5 2 This is a blank page...
Page 50: ...Section 6 Maintenance and Troubleshooting 6 6 This is a blank page...
Page 51: ...This is a blank page...