6. Installation
6.1
Siting
Choose
a
site
that
is
easily
accessible
throughout
the
winter.
The
CS705
Snowfall
Adapter
and
associated
rain
ga
u
ge
should
be
mounted
in
a
relatively
level
spot
that
is
representative
of
the
surrounding
area.
The
lip
of
the
funnel
needs
to
be
horizontal
and
76
cm
(30
in)
above
the
ground
or
higher
to
prevent
burial
by
snow.
The
ground
cover
around
the
ga
u
ge
should
be
natural
vegetation
or
gravel.
Avoid
mounting
the
ga
u
ge
over
concrete
or
paved
surfaces.
The
under
catch
of
winter
precipitation
by
antifreeze-based
ga
u
ges
is
directly
related
to
wind
speed.
Errors
due
to
wind
can
be
minimized
by
properly
siting
the
ga
u
ge.
The
preferred
ga
u
ge
site
is
in
a
natural
well
protected
location.
To
ensure
proper
catch,
an
angle
of
30°
to
45°
from
a
vertical
line
drawn
through
the
cent
re
of
the
ga
u
ge
orifice
to
the
surrounding
obstructions
should
be
maintained.
illustrates
the
proper
siting
of
a
ga
u
ge.
Ga
u
ges
sited
improperly
and
subjected
to
high
winds
will
under
catch
winter
precipitation
generating
erroneous
data.
An
improperly
sited
ga
u
ge
subjected
to
high
winds
can
be
damaged
by
the
wind.
FIGURE
6-1.
Proper
ga
u
ge
siting
CS705 Snowfall Adapter