Table 8-2: Extended SDI-12 commands for the CS475A
Command name
Command
format
Sensor
response
Configuration by sensor
Write Slope
Returns: New
slope, error code
aXWSS=xxx.xxxx
aD0!
atttn
a+xxx.xxxx+ee
Change the slope.
xxx.xxxx: new slope setting
ee: error code
To use this command, the System
Units command needs to be set
to 2 (
aXWSU=2!
)
Read Slope
Returns: Slope,
error code
aXRSS!
aD0!
atttn
a+xxx.xxxx+ee
Pull the slope out of memory.
xxx.xxxx: current slope
ee: error code
Write Stage
Reference
Returns: New
stage, error code
aXWSR=sss.ss!
aD0!
atttn
a+sss.ss+ee
Change stage reference to ‘sss.ss’
in configured units.
ee: error code
Read Stage
Reference
Returns: Current
stage reference,
error code
aXRSR!
aD0!
atttn
a+sss.ss+ee
Pull stage reference out of
memory.
sss.ss: stage reference from
memory in configured units
ee: error code
Write Calculated
Offset
Returns: New
offset, error code
aXWCO=ooo.oo!
aD0!
atttn
a+ooo.oo+ee
Change calculated offset value
ooo.oo: new offset in the
configured units
ee: error code
Read Calculated
Offset
Returns: Offset,
error code
aXRCO!
aD0!
atttn
a+ooo.oo+ee
Pull current calculated offset
value out of memory
ooo.oo: current calculated offset
value out of memory
ee: error code
CS475A Radar Water Level Sensor