CS125 Present Weather Sensor
12
8. CS125 internal connectors’ description
The CS125 has four standard IP66 rated glands. The first gland is by default used
by the power/communications line. This comprises the 7-30 V for the main
electronics, and the serial communications wires. The CS125 is supplied with 5 m
cable already connected.
The second gland is used for the 24 V feeds for the hood heaters fitted with a 5 m
cable.
Glands 3 and 4 are spare. If user alarms are connected they usually use gland 3
and if a CS215 is fitted this usually uses gland 4.
If the power cable is incorrectly wired to the CS125 then
damage can be done to the unit.
10 m is the longest length of the cable type supplied
recommended. In particular, additional RS485 communication
should be twisted pair. Please contact Campbell Scientific if
you wish to use a longer length of cable.
Figure 8-1. Connections
A configuration cable, part number 010817, is available from Campbell Scientific
that plugs directly into connector B, in place of the normal connector and cable.
CAUTION
CAUTION
Summary of Contents for CS125