COM100 Cellular Phone Package
6
Datalogger
Storage Capacity
Approx. Time for Entire Memory
# of Data Points
Collection at 1200 Baud
CR500
24,000
6.6 minutes
CR10
29,908
8.3 minutes
CR10X
62,280
17.3 minutes
21X
19,296
5.3 minutes
CR7
18,396
5.1minutes
5. Installation
DC112, VS1, COM200
4
(field modem)
Blue 9-Pin SC12 Cable
DATALOGGER
3
RJ11C
Interface
COM100
BLACK
Ground (G)
RED
+12 VDC
GREEN
Control Port*
Red LED
2
4 Pin RJ11C Connection
1
Power Control Cable
Coaxial Cable
to Antenna*
RJ11C Interconnect Cable
Control +12V G
Port
FIGURE 5-1. COM100 Wiring
•
Do not connect the Green wire (Crydom relay
control) to the sw12V power supply on the
black wiring panels used with the CR10 and CR10X
Dataloggers. The maximum input voltage to the
relay is +9 VDC. An input voltage greater than this
will damage the mini Crydom relay contained
within the power control cable.
•
A 50 Ohm Antenna must be connected to the
COM100 at all times. If a call is attempted without
an antenna connected, permanent damage to
COM100 can result which will void the warranty.
1
Connect the field modem patch cable to the 4-pin connector side of the
RJ-11C interface box. The phone modem will not work if it is connected
to the 8-pin connector.
2
When the cellular phone is turned on via the control port, the Red LED
switch on the RJ11C Interface box will flash for about 10 seconds. The
WARNINGS