INSTRUCTION MANUAL

COM100

Cellular Phone Package

Revision: 9/01

C o p y r i g h t   ( c )   1 9 8 7 - 2 0 0 1

C a m p b e l l   S c i e n t i f i c ,   I n c .

Summary of Contents for Com100

Page 1: ...INSTRUCTION MANUAL COM100 Cellular Phone Package Revision 9 01 C o p y r i g h t c 1 9 8 7 2 0 0 1 C a m p b e l l S c i e n t i f i c I n c ...

Page 2: ...l other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc dire...

Page 3: ...to Section 9 NOTE The COM200 or COM210 field phone modem when used with the COM100 Cellular Phone package supports 300 1200 2400 and 4800 baud connections Campbell Scientific datalogger serial ports support a 300 1200 and 9600 baud terminal connection Additional commands must be sent to the PC calling modem during the dialing sequence to allow a 2400 and 4800 baud modem connect speed with the fiel...

Page 4: ...This is a blank page ...

Page 5: ...Phone i e Motorola and the Electronic Serial Number ESN The ESN is located on a bar coded label on the back of the cellular phone The actual location of the ESN on the label can be seen in the example below and is shown as bold characters Example D57E1504 The ESN always consists of 8 characters LABEL 1 SUN19008SC MH2 376H D57E1504 416S 18 5F61 N0515281 To date March 1997 the ESN on all Motorola Ce...

Page 6: ...This is a blank page ...

Page 7: ...ar Phone Package includes Motorola M600 Transceiver Motorola p n 19370XNMSA RJ 11C Interface Motorola p n 519360 Crydom Relay built into Power and Control Cable Mounting Bracket CSI p n 10529 10 Coaxial Cable with male mini UHF and male Type N Conn Model 10531 Options to complete package include choose 1 phone modem 300 1200 2400 4800 9600 Baud Data Modem Model COM200 or COM210 300 1200 2400 4800 ...

Page 8: ...mensions 8 4 x 3 9 x 1 0 Operating Temperature 30 to 60 C Supply Voltage 10 to 16 VDC RF Power Output 3 watts nominal Average Current Quiescent 0 5 mA Standby 0 17 A On Line 1 8 A Antenna Termination 50 Ohm mini UHF female Control Relay Crydom D0061B Control Voltage 1 7 to 9 VDC Control Current 15 mA 5 VDC Output Rating 02 1 0 ADC 3 60 VDC See warnings page 4 ...

Page 9: ...ECIFIC ATION MIL D 34 64 TYPE I II REACTIV ATION TIME IN BAG 16 HOURS AT 250 F DESICCA NT ACTIVAT ED BAGGED FOR CONTEN TS 4 UNITS PACKAG E USE AND STATIC DEHUMID IFICATIO N O O CAMPBELL SCIENTIFIC INC COM200 MODEM S N 0002 MADE IN USA GND RING TIP Complies with Part 68 FCC rules FCC Registration No B9QUSA 75378 MM T Ringer Equivalence 0 6B Required Connector USOC RJ11C Canadian Load No 5 This equi...

Page 10: ... power the datalogger and transceiver from batteries alone unless the battery capacity is very large the batteries are changed frequently or the transceiver is switched on infrequently Since a battery is simply a storage device a power budget can be calculated to determine the battery capacity required per day using the following equation standby current drain time in standby mode on line current ...

Page 11: ...ged and at 25 C Model PS12LA BP12 BP24 Charging Source Notes 1 1 2 1 2 3 Battery 7 Ahr 12 Ahr 24 Ahr Approximate Operating days 7 12 24 1 10 watt solar panel recommended as charging source in remote applications model MSX10 2 12VDC regulator model CH12R 3 Larger enclosure required model ENC 16 18 For frequent fixed site calling applications without AC power the MSX20R Solar Panel or MSX20 and CH12...

Page 12: ...rydom relay control to the switched 12V power supply on the black wiring panels used with the CR10 and CR10X Dataloggers The maximum input voltage to the relay is 9 VDC An input voltage greater than this will damage the mini Crydom relay contained within the power control cable A 50 Ohm Antenna must be connected to the COM100 at all times If a call is attempted without an antenna connected permane...

Page 13: ...D CAMPBELL SCIENTIFIC INC COM210 MODEM MADE IN USA S N 1002 Complies with Part 68 FCC rules FCC Registration No B9QUSA 31402 MM T Ringer Equivalence 0 9B Required Connector USOC RJ11C Canadian Load No 5 This equipment complies with the requirements in Part 15 of FCC Rules for Class A computing device Operation of this equipment in a residential area may cause unacceptable interference to radio and...

Page 14: ...ION MIL D 3464 TYPE I II REACTIVATION TIME IN BAG 16 HOURS AT 250 F DESICCANT ACTIVATED BAGGED FOR CONTENTS 4 UNITS PACKAGE USE AND STATIC DEHUMIDIFICATION DO NOT EAT UNITED DESICCANTS GATES 101CHRISTINE BELEN NEW MEXICO 87002 DESI PAK SPECIFICATION MIL D 3464 TYPE I II REACTIVATION TIME IN BAG 16 HOURS AT 250 F DESICCANT ACTIVATED BAGGED FOR CONTENTS 4 UNITS PACKAGE USE AND STATIC DEHUMIDIFICATIO...

Page 15: ...n file As mentioned previously the COM200 COM210 phone modem used with the COM100 Cellular Phone package supports 300 1200 2400 and 4800 baud connections Campbell Scientific datalogger serial ports support a 300 1200 and 9600 baud terminal connection Additional commands must be sent to the PC calling modem during the dialing sequence to allow a 2400 and 4800 baud modem connect speed Bandwidth limi...

Page 16: ...trolling the relay high to turn the power on and a second Instruction 92 sets the port low In these examples control port 1 controls the relay The following program switches the transceiver on at midnight for 15 minutes CR10X Table 1 Program 01 10 0 Execution Interval seconds 01 If time is P92 1 0 Minutes Seconds into a 2 1440 Interval same units as above 3 41 Set Port 1 High 02 If time is P92 1 1...

Page 17: ...Or one might want to power the transceiver for one hour at 10 a m and at 10 p m CR10X Table 1 Program 01 10 0 Execution Interval seconds 01 If time is P92 1 600 Minutes Seconds into a 2 720 Interval same units as above 3 41 Set Port 1 High 02 If time is P92 1 660 Minutes Seconds into a 2 720 Interval same units as above 3 51 Set Port 1 Low Table 2 Program 02 0 0 Execution Interval seconds Table 3 ...

Page 18: ...y voltage of 12VDC The system will operate between 10 and 16VDC Since the COM100 draws 1 8 Amps during transmission lead acid or gel cell type of batteries PS12LA BP12 BP24 must be used Do not use alkaline batteries CSI Model BPALK or PS12ALK as a power source for the cellular phone Alkaline batteries have a high internal resistance and cannot source the high current requirements of the COM100 Q I...

Page 19: ...he antenna directly at the cell tower will be required Q Does your datalogger program contain the necessary control instructions to turn the cellular phone on and off The COM100 requires a logic control port to turn the cellular phone on The green wire of the power control cable should be wired to a control port Check to ensure that the screw terminals are not crimped on the green insulation of th...

Page 20: ...is activated 2 The Campbell Scientific software will display an activity of communication as the link is being established Assuming the above items are O K the software should display in the activity window screen something such as ATDT Where the is the telephone number listed in the dialing path of the software for the datalogger you are trying to call The local modem attached to the computer wil...

Page 21: ...red when the phone is turned back on This includes the on or off state of the phone at the time the ignition sense line green wire was set low 0V In unattended installations the datalogger will NOT power up the cellular phone if the red LED power indicator switch has been manually turned OFF no longer lit while under datalogger control There is a specific sequence that causes this failure to happe...

Page 22: ...non volatile memory remove power from the ignition sense line by setting the control port low 0V From this point on the phone will reliably power up and down under datalogger control A sample listing of datalogger program code is shown below to assist a user in steps 3 and 5 from above CR10 Table 1 Program 01 1 0 Execution Interval seconds 1 If Flag Port P91 1 11 Do if Flag 1 is High 2 41 Set Port...

Page 23: ...This is a blank page ...

Page 24: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...