6.1 Base station requirements
A computer running Campbell Scientific LoggerNet software with access to the Internet is
needed.
6.2 Data logger site equipment
l
CELL200-series module with power cable (included with module)
l
Data logger — CR1000X series, CR300 series, CR6 series, CR1000, CR3000, CR800 series,
CR5000, and GRANITE 6/9/10
l
Module Interface, see
Module communications connections
l
Environmental Enclosure — ENC10/12, ENC12/14, or ENC16/18
If connecting to CS I/O port:
SC12 cable (preferred for CR1000X series, CR300 series, CR6 series, CR1000, CR3000,
CR800 series, CR5000, and GRANITE 6/9/10 data loggers ) — connects the module to
current data logger with a CS I/O port. See
SC105 Interface — connects the module to any data logger with a CS I/O port. It must
be configured using Device Configuration Utility. Settings should be:
l
CS I/O Mode: Modem Enable
l
CS I/O ME Baud Rate: 9600
l
RS-232 Mode: Modem (default)
l
Baud Rate:
l
115.2K for CR1000X series, CR300 series, CR6 series, CR1000, CR3000, CR800
series, CR5000, and GRANITE 6/9/10 data loggers