13
Operating Instructions and Assembly Instructions
Airless Paint Sprayers
www.chpower.com
Finishing Touches/Shutdown
ClEANUP FOr ChANGING PAINTS Or
TEmPOrAry STOrAGE FOr mOrE
ThAN ONE NIGhT
(Continued)
17. Make sure prime/spray control is in
SPRAY position to reduce dribbling.
18. Turn pressure to LOW (completely
counterclockwise).
19. Turn power switch to OFF position.
20. With gun pointed in safe direction
pull trigger with lock released to
relieve any pressure in hose.
21. Engage gun trigger lock.
22. Clean buckets and dispose of any
waste paint and cleaning fluid in
an environmentally responsible
manner.
23. Clean tip guard with cleaning brush
and cleaning fluid.
NOTE:
At this point, pump, hose and
spray gun are clean, but still require
further preparation for storage of more
than one day.
17
Prime/Spray is
in SPRAY/ROLL
Position
18
Turn Pressure to LOW
(completely counterclockwise)
Pull Gun Trigger with
Trigger Lock Released
Engage Gun Trigger Lock
21
13
20
To Lock
Locked