background image

MW2500 Series

5

www.chpower.com

Operating Instructions and Parts List

Maintenance

 

 

Disconnect, tag and lock out 
power source, then release 
all pressure from the system 
before attempting to install, service, 
relocate or perform any maintenance.

Check compressor often for any visible 
problems and follow maintenance 
procedures each time compressor is 
used.

 

Safety valve must  

 be replaced if it 

cannot be actuated or it leaks air after 
ring is released.

1.  Turn compressor off and release 

pressure from system. (To release 
pressure from system, pull ring 
on ASME safety valve. Deflect 
escaping air by shielding valve with 
one hand as you pull ring with 
other hand.) Pull ring until tank is 
empty.

 

A large amount of  

 fast moving air 

will be released when the safety valve 
is opened with pressure in the tank. 
Wear ANSI approved Z87.1 safety 
glasses.

2.  Drain moisture from tank by 

opening drain valve underneath 
tank. Tilt tank to remove all 
moisture.

3.  Clean dust and dirt from tank, 

air lines and pump cover while 
compressor is still OFF.

aSMe SaFety vaLve

 

Do not remove or   

 attempt to adjust 

the safety valve!

Check the safety valve by performing 
the following steps: 

1.  Plug the compressor in and run 

until shut off pressure is reached. 

2.  Wearing safety glasses, pull the 

ring on the safety valve to release 
pressure from compressor tank. 
Use your other hand to deflect 
fast-moving air from being 
directed toward your face. 

3.  The safety valve should 

automatically close at 
approximately 40 psi - 50 psi. If 
the safety valve does not allow 
air to be released when you pull 
on the ring, or if it does not close 
automatically, it MUST be replaced.

Figure 4

DraIn tank

With compressor shut off and pressure 
released, drain moisture from tank by 
opening drain valve underneath tank. 
Tilt tank to completely drain moisture.

cLeanInG

Turn power OFF and clean dust and 
dirt from pump cover, tank, and air 
lines.

IMPOrtant:

 Unit should be located 

as far from spraying area as hose will 
allow to prevent over-spray from 
clogging air filter.

LUbrIcatIOn.

This is an oilless type compressor 
requiring no lubrication.

enD OF OPeratIOn/StOraGe

1.  Turn ON / OFF switch to the OFF 

position.

2.  Unplug power cord from wall 

outlet and wrap around handle 
area to prevent damage when not 
in use.

3.  Wearing safety glasses drain tank 

of air by pulling the ring on the 
safety valve. Use other hand to 
deflect fast moving air from being 
directed toward your face.

4.  Drain tank of condensation by 

opening drain valve on bottom 
of tank. Tank pressure should be 
below 10 psi when draining tank.  

5.  Air hose should be disconnected 

from compressor and hung open 
ends down to allow any moisture 
to drain.

6.  Compressor and hose should be 

stored in a cool, dry place.

technIcaL ServIce

For information regarding the 
operation or repair of this product, 
please call 1-800-543-6400.

MaIntenance ScheDULe

OPeratIOn

DaILy

WeekLy

MOnthLy

DRAIN TANK

l

CHECK SAFETY VALVE

l

CLEAN UNIT

l

Summary of Contents for MW2500 Series

Page 1: ...manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the foll...

Page 2: ...motor exterior free of oil solvent or excessive grease An ASME code safety relief valve with a setting no higher than 170 psi MUST be installed in the tank for this compressor The ASME safety valve m...

Page 3: ...eam paint spray sandblast areas or any other source of contamination This debris will damage the motor Grounding instructions 1 This product is for use on a nominal 120 volt circuit and has a groundin...

Page 4: ...re chuck or tool to end of hose 7 Turn regulator knob clockwise to the right to desired pressure of tool being used Operation START UP Do not attach air tools to open end of the hose until start up is...

Page 5: ...t moving air from being directed toward your face 3 The safety valve should automatically close at approximately 40 psi 50 psi If the safety valve does not allow air to be released when you pull on th...

Page 6: ...s off 1 Loose connections at fittings tubing air line or tool 1 Check all connections with soap and water solution If a leak is detected 1 tighten or 2 remove fitting and apply pipe tape to threads an...

Page 7: ...7 Notes MW2500 Series www chpower com Operating Instructions and Parts List...

Page 8: ...43 6400 Please provide following information Model number Serial number if any Part description and number as shown in parts list Address any correspondence to Campbell Hausfeld Attn Customer Service...

Page 9: ...feet n 3 18 Screw n 3 19 Pressure switch WL052900AV 1 20 Manifold tube includes nut and fitting WL053000AV 1 21 Regulator includes knob cap and screw WL053100AV 1 22 Outlet gauge WL053200AV 1 23 1 4...

Page 10: ...ll 1 800 543 6400 Please provide following information Model number Serial number if any Part description and number as shown in parts list Address any correspondence to Campbell Hausfeld Attn Custome...

Page 11: ...backer 1 8 Exhaust valve 1 9 Valve plate 1 10 Intake valve 1 11 Intake valve backer 1 12 O ring SV627400AV 1 13 Cylinder 1 14 Motor assembly 1 15 Pulley 1 16 Piston bearing 1 17 Eccentric pulley 1 18...

Page 12: ...bricants and adjustment E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component...

Page 13: ...RVER CES INSTRUCTIONS Ne pas jeter Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symb...

Page 14: ...cart du compresseur les pi ces mobiles et chaudes peuvent causer des blessures et ou des br lures 10 Si l quipement vibre anormalement ARR TER le moteur et l inspecter imm diatement La vibration est...

Page 15: ...ette soupape est situ e sur la base du r servoir Utiliser cette soupape pour purger l humidit du r servoir quotidiennement afin de r duire le risque de corrosion R initialisation du moteur non visible...

Page 16: ...on ON MARCHE Laissez le compresseur tourner pendant 30 minutes 6 Mettre l interrupteur marche arr t la position OFF ARR T 7 D brancher le cordon d alimentation Le compresseur est maintenant pr t tre u...

Page 17: ...upape de s ret de la mani re suivante 1 Brancher le compresseur et le faire fonctionner jusqu ce qu il atteigne la pression d arr t voir proc dure de fonctionnement 2 Porter des lunettes de s curit ti...

Page 18: ...solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban tuyau pour les filets et remonter 2 Robinet de vidange desserr 2 Resserrer 3 V rifier toute fui...

Page 19: ...19 Fr Notes S rie MW2500...

Page 20: ...d le Code imprim sur l unit Description de la pi ce et son num ro Adresser toute correspondance Campbell Hausfeld Attn Customer Service 100 Production Drive Harrison OH 45030 Instructions d Utilisatio...

Page 21: ...3 19 Manostat WL052900AV 1 20 Tube de collecteur inclut crou et raccord WL053000AV 1 21 R gulateur inclut bouton bouchon et vis WL053100AV 1 22 Jauge de sortie WL053200AV 1 23 Coupleur industriel m le...

Page 22: ...00 S il vous pla t fournir l information suivante Num ro de mod le Code imprim sur l unit Description de la pi ce et son num ro Adresser toute correspondance Campbell Hausfeld Attn Customer Service 10...

Page 23: ...1 10 Soupape d aspiration 1 11 Appui de soupape d admission 1 12 Joint torique SV627400AV 1 13 Cylindre 1 14 Moteur quip 1 15 Poulie 1 16 Roulement de piston 1 17 Excentrique poulie 1 18 Essieu excent...

Page 24: ...ants filtres et joints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle pan...

Page 25: ...IGA TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministra...

Page 26: ...ntenga los dedos alejados del compresor cuando est funcionando las piezas en movimiento o calientes le ocasionar an heridas y o quemaduras 10 Si el equipo comienza a vibrar excesivamente APAGUE la uni...

Page 27: ...ruptor en la posici n ON para reanudar el trabajo Si se activa el protector de sobrecarga se debe dejar enfriar el motor durante aproximadamente 30 minutos antes de que se reinicie Instalaci n Colocac...

Page 28: ...sici n ON encendido Deje que el compresor funcione durante 30 minutos 6 Coloque el interruptor de encendido apagado en la posici n OFF apagado 7 Desenchufe el cable de corriente Ahora el compresor est...

Page 29: ...y libere toda la presi n despu s Abra la llave de drenaje ubicada debajo del tanque para drenarle toda la humedad Incline el tanque para drenar completamente la humedad Humedad en el aire comprimido...

Page 30: ...or 1 Conexiones flojas en los accesorios tuber a l nea de aire o herramienta 1 Revise todas las conexiones con una soluci n de agua y jab n Si detecta una fuga 1 ajuste o 2 retire las conexiones y apl...

Page 31: ...31 Sp Notas Serie MW2500...

Page 32: ...o N mero de serie de haberlo Descripci n y n mero del repuesto seg n la lista de repuestos Puede escribirnos a Campbell Hausfeld Attn Customer Service 100 Production Drive Harrison OH 45030 Operating...

Page 33: ...Tornillo n 3 19 Presostato WL052900AV 1 20 Tubo del colector incluye tuerca y accesorios WL053000AV 1 21 Regulador incluye perilla tapa y tornillo WL053100AV 1 22 Man metro de salida WL053200AV 1 23...

Page 34: ...ordenar repuestos s rvase llamar al distribuidor m s cercano a su domicilio S rvase darnos la siguiente informaci n N mero del modelo N mero de serie de haberlo Descripci n y n mero del repuesto seg...

Page 35: ...1 13 Cilindro 1 14 Ensamblaje del motor 1 15 Polea 1 16 Casquillo del pist n 1 17 Exc ntrica polea 1 18 Eje exc ntrico 1 19 Correa WL048500AV 1 20 Cojinete 2 21 Pist n 1 22 Aro del pist n 1 23 Anillo...

Page 36: ...tc F Art culos adicionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contraria...