background image

entangled in moving components,
causing equipment damage and or
personal injury.

9. Keep all persons away from parts

that move or become hot during
operation.

10. Be sure all powered devices are shut

off prior to connecting them to the
generator.

11. Keep the generator clean and well

maintained at all times.

Never operate this 
generator in an
explosive atmosphere
or poorly ventilated
area.

!

WARNING

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

IN951300AV  2/01

Operating Instructions

Models GN356402AC, GN356502AC, and GN356602AC 

Generators

BUILT TO LAST

TM

These generators are powered by air-
cooled four cycle engines and designed
to run at maximum RPM and give a
continuous wattage as rated. 

When unpacking, inspect carefully for
any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service.

1. Before starting or

servicing any
generator, read and
understand all
instructions. Failure
to follow safety
precautions or instructions can cause
equipment damage and/or serious
personal injury. Engine instructions
for these units are contained in a
separate manual. Retain all manuals
for future reference.

2. Never use this generator for any

application other than that specified
by the manufacturer. Never operate
this generator under conditions not
approved by the manufacturer.
Never attempt to modify this
generator to perform in any manner
not intended by the manufacturer.

3. For maintenance and repairs, use

only products and parts
recommended by the manufacturer.

4. Be sure that the generator is

properly grounded to an external
ground path prior to operation.
Refer to the section entitled

“Grounding Instructions” for proper
grounding procedures.

5. Be sure that the generator is

operated only by persons who have
read and understand these
instructions.

6. Be sure that the generator is placed

on a flat level surface prior to and
during operation. The generator
must not slide or shift during
operation.

7. Keep all persons away from the

generator during operation.

8. Do not allow persons wearing loose

clothing or jewelry to start or
operate the generator. Loose
clothing or jewelry may become

MANUAL

Fig. 1 - Assembled Units GN356402AC and GN356502AC

For parts, product & service information

visit 

www.chpower.com

or call 

1-800-803-1436

© 2001 Campbell Hausfeld / Scott Fetzer

Description

Unpacking

General Safety

Summary of Contents for GN356402AC

Page 1: ...ions Failure to follow safety precautions or instructions can cause equipment damage and or serious personal injury Engine instructions for these units are contained in a separate manual Retain all ma...

Page 2: ...t eight feet in length and 5 8 inch diameter d A non ferrous rod at least eight feet in length 1 2 inch in diameter and approved for grounding purposes Any rod or pipe used for grounding must be drive...

Page 3: ...l power Keep cords at minimum possible length Precautions must be taken to prevent electrical back feeding into utility systems This requires isolation of the electrical system To isolate the electric...

Page 4: ...periods of time the following pre storage procedures should be performed Maintenance 1 Make sure engine oil is filled to the proper level 2 Drain all fuel from the tank lines and carburetor 3 Remove...

Page 5: ...he wiring diagram clean and reconnect all wiring 3 Replace capacitor 4 Test winding resistance replace winding if necessary 5 Test rectifier replace if necessary 1 Adjust engine speed 2 Test rectifier...

Page 6: ...hipping damage purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual s supplied with product D Pre delivery service i e assembly oil o...

Page 7: ...ui n est pas sp cifi e par le fabricant Ne jamais faire fonctionner cette g n ratrice sous des conditions qui ne sont pas approuv es par le fabricant Ne jamais essayer de modifier cette g n ratrice af...

Page 8: ...ndant le remplissage S assurer que le bouchon de r servoir essence soit en place avant le d marrage du moteur Permettre que le moteur se refroidisse pour au moins deux minutes avant le remplissage Ne...

Page 9: ...deur de 8 pi 2 4 m ou enterr s dans une tranch e aussi creuse que possible D MARRAGE 1 V rifier le niveau d huile et d essence 2 Enlever toutes charges lectriques de la g n ratrice 3 Mettre l interrup...

Page 10: ...ique de r serve doit tre effectu par un lectricien qualifi dipl m ou brevet AVERTISSEMENT AVERTISSEMENT USAGE PEU FR QUENT Pour viter la difficult avec le d marrage en cas d usage peu fr quent faire f...

Page 11: ...r de nouveau tous les fils 3 Remplacer le condensateur 4 Faire l essai de la r sistance de l enroulement remplacer l enroulement si n cessaire 5 Faire l essai du redresseur remplacer si n cessaire 1 R...

Page 12: ...r sultant d un accident de dommage pendant l exp dition d une utilisation abusive de la n gligence ou d une utilisation ne respectant pas les instructions donn es dans le s manuel s accompagnant le pr...

Page 13: ...qualquer outra aplica o que n o tenha sido especificada pelo fabricante e nunca opere este gerador sob condi es n o aprovadas pelo fabricante N o tente modificar este gerador para que ele desempenhe d...

Page 14: ...E API e quantidade de abastecimento 2 Recomenda se enfaticamente o uso do Interruptor do Circuito de Falha de Aterramento El trico Ground Fault Circuit Interrupter GFCI Os Interruptores de Circuito de...

Page 15: ...u a voltagem de sa da AMACIAMENTO DO MOTOR Ap s a partida inicial o motor deve ser amaciado de acordo com as instru es do fabricante Consulte o manual do motor para os procedimentos adequados de amaci...

Page 16: ...amente 30 minutos por semana ARMAZENAGEM Se o gerador n o for usado por um longo prazo devem ser observados os procedimentos de pr armazenagem abaixo 1 Certifique se de que o leo do motor esteja no n...

Page 17: ...a fia o el trica 3 Substitua o capacitor 4 Teste a resist ncia do enrolamento e substitua se necess rio 5 Teste o retificador substitua se necess rio 1 Ajuste a velocidade do motor 2 Teste o retificad...

Page 18: ...ao seu caso C Qualquer falha resultante de acidente dano de remessa abuso por parte do comprador neglig ncia ou da n o opera o do produto de acordo com as instru es no s manual ais do propriet rio que...

Page 19: ...trucciones para los motores de estos generadores se encuentran en otro manual Guarde todos los manuales como referencia para el futoro 2 Nunca utilice este generador salvo para un uso especificado por...

Page 20: ...llene el tanque Aseg rese de que la tapa del tanque est bien ajustada antes de prender el motor Deje que el motor se enfr e por dos minutos como m mimo antes de llenar el tanque Nunca utilice una mez...

Page 21: ...rosa de 8 pies de longitud y 1 2 13 mm pulgada de di metro como m nimo y que ha sido aprobada como toma de tierra Cualquier ca o o barra que se use como toma de tierra debe ser barrenado hasta ocho pi...

Page 22: ...VERTENCIA La instalaci n del generador como fuente de energ a de reserva debe ser hecha por un electricista capacitado licenciado o habilitado USO INFRECUENTE Si el generador se usa con poca frecuenci...

Page 23: ...motor 2 Limpie y reconecte los cables consultando el esquema al mbrico 3 Reemplace el condensador 4 Mida la resistencia del arrollamiento reempl celo si es necesario 5 Examine el rectificador reempl...

Page 24: ...ente al operar productos de acuerdo con las instrucciones proporcion en el manual es del propietario provisto el producto D Servicio de Pre salida es decir ensamblaje aceite o lubricantes y ajuste E A...

Reviews: