Output 1
∑
Output 1
Off1,On2:X
Off1,On2:X
∑
Output 1
∑
Output 1
PIN please
PIN please
21
Step by step guide
Display
Input
The controller offers two separately con
fi
g-
urable outputs.
Each output can be operated either as switch-
able DC supplier or as potential-free relay
contact. The mode selector (DIP switch) is
located on the back side of the control unit.
The meaning of the DIP switch setting is ex-
plained on the next page. You will
fi
nd the
speci
fi
cation of the outputs in chapter
Techni-
cal Data/Speci
fi
cation
on page 30.
If operated as DC supplier the ports can work
as open current or closed current terminals.
If used as relay contacts, the ports can work
either as NO or NC contact.
DC mode (default) Relay mode
1
No power out in
normal status
Contact open in
normal status
2
Power out in nor-
mal status
Contact closed in
normal status
Factory default for output 1 is DC mode and
open current, i.e. power off in normal status.
An electric strike can be connected to this
port without changing any settings.
How to operate output 1.
CONNECTORS
Out 1