Maintenance and Cleaning 

 

  Proper maintenance and cleaning can keep instruments working properly and 

will lengthen its lifetime.  

  ABS casing will give some chemical resistance to weakly acidic and alkaline 

liquids.  

  Do not spray your chosen cleaner directly on to the unit when cleaning 

  Ensure the unit is unplugged from the power supply and cooled down 

completely before commencing with cleaning. 

  Wear appropriate PPE equipment during the cleaning process. 

  Only use recommended cleaners below:  

Dyes 

Isopropyl alcohol 

Construction 

materials 

Water containing surfactant/ 

isopropyl alcohol 

Cosmetics 

Water containing 

surfactant / isopropyl alcohol 

Foodstuffs 

Water containing surfactant 

Fuels 

Water containing surfactant 

 

  If the instrument will not be in operation for an extended period of time, please 

switch off and store in a dry, clean environment.  

 

Faults and Troubleshooting  

 

Instrument is not powering on 

  Check whether the power line is plugged in 

  Check whether the fuse is broken or loose 

Stir speed is not reaching set point 

  Excessive medium viscosity may cause abnormal speed reduction of the 

motor. This instrument has only been verified for stirring water and mediums 

with a similar viscosity). Try the unit with a small quantity of water to check the 

Summary of Contents for MS-H280-Pro

Page 1: ...MS H280 Pro Round Ceramic Coated Steel Hotplate Stirrer with LED display USER MANUAL 1200464...

Page 2: ...x 6 Permitted conditions of operation 6 Setting up 7 Operation 8 Controls 8 Display 9 Instructions for use 10 Using the temperature sensor 10 Maintenance and Cleaning 11 Faults and Troubleshooting 11...

Page 3: ...Steel Hotplate Stirrer has a double LED display and heats up to 280 C with a stirring speed range of 100 1500rpm Heating and stirring are controlled independently and each function can be used separa...

Page 4: ...pply voltage match and ensure the socket is properly grounded When working with the MS H280 Pro use appropriate PPE to avoid risk of injury caused by o Splashing and evaporating liquids o The release...

Page 5: ...ature sensor is used the tip of the measuring sensor must be at least 5 10mm from vessel bottom and wall The instrument can only be disconnected from the mains power supply by pulling out the connecto...

Page 6: ...pin Bar 50mm x 8mm 1 Permitted conditions of operation This device is designed to operate under the following conditions Indoor use only Use in well ventilated area Permitted ambient temperature range...

Page 7: ...Setting up You must observe a minimum distance of 10cm between the unit and any other object including the wall 10cm Figure 1...

Page 8: ...ependent controls for temperature and speed Both of these functions can be used together and separately if required For the stirring function an appropriate magnetic stirring bar is required Diagram C...

Page 9: ...t 3 Probe Holder Port Port for external temperature probe holder 4 Stir Speed Stirring speed control dial Rotate clockwise to increase speed and counter clockwise to decrease Push button in to turn fu...

Page 10: ...d target temperature and push in the dial to commence heating To turn heating off push the dial in again When heating is not in use the temperature LED will display as OFF 4 Stirring Rotate the dial t...

Page 11: ...ing the cleaning process Only use recommended cleaners below Dyes Isopropyl alcohol Construction materials Water containing surfactant isopropyl alcohol Cosmetics Water containing surfactant isopropyl...

Page 12: ...ines Construction in accordance with the following safety standards EN 61010 1 UL 3101 1 CAN CSA C22 2 1010 1 EN 61010 2 10 Construction in accordance with the following EMC standards EN61326 1 Associ...

Page 13: ...otplate stirrer If you need to order any of the below we invite you to visit our website www camlab co uk Cat No Descriptions 1189944 PT1000A Temperature 230mm Probe for all Camlab Choice digital hotp...

Page 14: ...cts in materials and workmanship under normal use and service for a period of 24 months from the date of invoice and is extended only to the original purchaser It shall not apply to any product or par...

Reviews: