30
Operating Instructions
Programmable multi-transducer with PROFIBUS-DP Interface
SINEAX DME 406
2. Scope of supply
Transducer
(Fig. 1)
1 blank type label
(Fig. 2) for recording programmed set-
tings
1 CD
with a DBF fi le, Operating Instructions in three lan-
guages (German, French, English), interface defi nition and
bitmap (Fig. 3)
100V
2A
50Hz
3N~
1
2
3
4
000
15
16
17
18
19
20
21
22
23
24
25
26
VD
RxD/TxD –P
RxD/TxD –N
Shield
RxD/TxD –P'
RxD/TxD –N'
DGND
Reset
BF
BA
BD
GND
PROFIBUS
Fig. 1
Fig. 2
Fig. 3
3. Brief description
SINEAX DME 406
(Fig. 1) is a programmable transducer with
a PROFIBUS-DP Interface that simultaneously measures
several variables of a heavy-current power systems.
The certifi ed device conforms to the PROFIBUS standard
EN 50 170. The PROFIBUS is an open fi eld-bus standard
independent of manufacturers with a wide range of applica-
tions. The PROFIBUS supports the communication of devices
from different manufacturers without special adaptations to
the interface.
The communication characteristics of the SINEAX DME 406
are defi ned in a DBF fi le (Device Basic data File). This fi le is
made available by the device manufacturer.
The transducer is also equipped with an RS 232 serial in-
terface to which a PC with the corresponding software can
be connected for programming or accessing and executing
useful ancillary functions.
The usual methods of connection, the rated values of the
input variables and the type of internal energy metering are
the main parameters that can be programmed.
The ancillary functions include a power system check, a
facility for printing rating labels and provision for reading
and resetting the energy meter.
The transducer fulfi ls all the essential requirements and re-
gulations concerning electromagnetic compatibility
(EMC)
and
safety
(IEC 1010 resp. EN 61 010). It was developed
and is manufactured and tested in strict accordance with
the
quality assurance standard
ISO 9001.
The following symbols in the Operating Instructions indicate
safety precautions which must be strictly observed:
Contents
1. Read fi rst and then … .............................................. 30
2. Scope of supply ........................................................ 30
3. Brief description ........................................................ 30
4. Ordering information ................................................. 31
5. Technical data ........................................................... 31
5.1 Measured values that are available at the bus
interface, depending on the application ............ 33
5.2
Resetting
............................................................ 34
5.3 Programming the SINEAX DME 406 .................. 34
6. Mounting ................................................................... 36
7. Electrical connections ............................................... 37
8. Commissioning ......................................................... 41
9. Maintenance .............................................................. 41
10. Releasing the transducer .......................................... 41
11. Dimensional drawings ............................................... 41
12. Safety notices ........................................................... 42
13. Declaration of conformity .......................................... 42
1. Read fi rst and then …
The proper and safe operation of the device
assumes that the Operating Instructions are
read
and the safety warnings given in the
sections
6. Mounting
8. Commissioning
are
observed
.
The device should only be handled by appropriately trained
personal who are familiar with it and authorized to work in
electrical installations.
Unauthorized repair or alteration of the unit invalidates
the warranty!
Summary of Contents for SINEAX DME 406