background image

13

7

All large bore ORBIT

valves are also equipped  

with a lower lube fitting

in the pressure area of the 

valve. This is a safe vent 

lube fitting.

8

Remove the cap slowly

to be sure the ball check in 

the fitting has sealed off 

the line pressure.               

Do not remove any parts 

other than this cap.

9

Thread the safe vent

coupler to the lube fitting. 

Before attaching the grease 

gun be sure the output 

capacity is higher than the 

line pressure.

10

Two complete strokes

on the grease gun provide 

sufficient lubrication.      

Cycle the valve if possible to 

evenly distribute the grease. 

Excess grease will discharge 

into the system piping.

11

ORBIT Grease Seal

valves are equipped with a 

safe vent lube fitting in the 

seat area of the valve.

12

Lubrication is identical

to steps 8 - 10 except 

lubricate until the leak 

stops.

13

All ORBIT valves

(except O.S.&Y. design) 

equipped with diaphragm 

actuators are lubricated 

through the upper lube 

point on the valve bonnet. 

No line pressure will be 

encountered.                   

Two strokes of the grease 

gun provide adequate 

lubrication. Excess grease 

will make the position 

indicator difficult to see.

14

O.S.&Y. ORBIT valves

equipped with diaphragm 

actuators are lubricated at 

the lube point on the 

adapter sleeve* above the 

line pressure.                   

Two strokes of the grease 

gun provide adequate 

lubrication. Excess grease 

will make the position 

indicator difficult to see.

* New style ORBIT diaphragm 

actuators have grease fitting 

installed in actuator case.

(CONTINUED ON NEXT PAGE)

P R O C E S S  V A L V E S

INSTALLATION, OPERATION AND MAINTENANCE - LUBRICATION

(CONTINUED FROM PREVIOUS PAGE)

CT-ORB-IOM/6

05/08 ION-3M

®

ORBIT

Summary of Contents for ORBIT GP-6

Page 1: ...ORBIT ORBIT Installation Operation and Maintenance P R O C E S S V A L V E S...

Page 2: ...roper installation and maintenance of ORBIT Valves and Actuators Step by step procedures should be followed closely to prevent damage to the valves and or actuators or injury to personnel This manual...

Page 3: ...es 10 Valve Illustrations Showing Lube Points 11 LUBRICATION Lubrication Schedule and Recommended Lubricants 12 Valve and Actuator Lubrication 12 STEM PACKING ADJUSTMENT Stem Packing Adjustment 15 Ste...

Page 4: ...cks and scratches 5 On handwheel valves cycle fully open and fully closed to check for ease of operation Check indicator rod travel against dimensions on page 8 to verify full stem travel 6 For valves...

Page 5: ...d easier operation 6 The words preferred pressure end have been abbreviated to Pref Pres End and can be found stamped on one end connection This stamping is marked with red paint 7 When possible ORBIT...

Page 6: ...mponents that are screwed into threaded valves 14 For weld end valves the temperature required to weld the valve into the line will exceed the rated working temperature of the valve ORBIT valves with...

Page 7: ...been abbreviated to Pref Pres End and are stamped on one end connection It is marked with red paint for easy identification 6 On piston actuated valves a gas over oil tank is provided to assure smoot...

Page 8: ...specified on the nameplate the minimum actuator pressure should always be within 5 psi 0 3 bar of maximum pressure 14 Connect the opening air supply for the diaphragm actuator to the bottom point A C...

Page 9: ...r supply to this point will keep the actuator from opening the valve 21 Also on LS spring close piston actuators the pipe plug on top of the gas over oil tank must be replaced with the filter breather...

Page 10: ...00 1 3 4 44 2 3 x 1 13 16 x 3 50 80 x 46 x 80 2500 1 3 4 44 3 4 x 3 x 4 80 100 x 80 x 100 150 300 1 1 2 38 3 4 x 3 x 4 80 100 x 80 x 100 600 1 3 4 44 3 4 x 3 x 4 80 100 x 80 x 100 900 1500 2 1 4 57 3...

Page 11: ...4 4 3 4 2 1 4 6 x 4 x 6 16 3 4 4 24 3 4 4 3 4 24 1 6 3 4 6 3 4 16 3 4 3 2 16 3 4 4 3 4 24 1 6 3 4 6 3 4 6 8 3 4 2 1 2 8 x 6 x 8 16 3 4 4 1 4 24 7 8 5 1 2 24 1 1 8 7 1 2 7 3 4 12 3 4 4 1 4 1 1 2 16 7 8...

Page 12: ...3 4 24 1 5 8 11 1 2 12 3 4 24 2 15 1 4 16 8 24 1 3 8 8 3 4 8 3 4 24 1 5 8 11 1 2 12 3 4 24 2 15 1 4 16 10 x 8 x 10 24 1 7 8 13 1 4 13 1 2 24 2 1 2 19 1 2 20 1 2 10 32 1 3 8 9 1 4 9 1 4 24 1 7 8 13 1 4...

Page 13: ...OPERATION AND MAINTENANCE VALVES WITH ONE LUBE POINT CT ORB IOM 6 05 08 ION 3M ORBIT PACKING ADJUSTMENT BOLTS DO NOT REMOVE WHEN VALVE IS UNDER PRESSURE PACKING FITTING NEVER REMOVE PACKING FITTING NE...

Page 14: ...grease gun provides adequate lube penetration CONTINUED ON NEXT PAGE ORBIT RECOMMENDED LUBRICATION SCHEDULE The frequency of valve lubrication should be based on user s past experience with installed...

Page 15: ...area of the valve 12 Lubrication is identical to steps 8 10 except lubricate until the leak stops 13 All ORBIT valves except O S Y design equipped with diaphragm actuators are lubricated through the u...

Page 16: ...d reach the level indicated in the chart below If the fill plug is removed in the OPEN position actuator pneumatic pressure will be encountered if the system is under pressure Personal injury and or d...

Page 17: ...ealed off the packing chamber pressure and replacing it with the type of plastic packing that is shown on the nameplate Do not substitute without 6 consulting the chart on page 17 Replace the adjustme...

Page 18: ...ressure by the stem packing rings is maintained by the compression applied to the gland flange and retainer bolts 13 If a stem leak occurs more compression can be applied by evenly adjusting the hex n...

Page 19: ...land which forces a brass friction plug against the valve stem 4 The conventional type Packing Gland Assembly uses braided packing rings and gland studs with nuts Adjustment is identical to O S Y valv...

Page 20: ...e not owned by Cameron Trademark Owner CARPENTER 450 Carpenter Technology Corp HASTELLOY Haynes International Inc INCONEL INCO Nickel Sales Inc LATROBE Timkin Latrobe Steel MONEL INCO Alloys Internati...

Page 21: ...P R O C E S S V A L V E S NOTES CT ORB IOM 6 05 08 ION 3M ORBIT...

Page 22: ...P R O C E S S V A L V E S NOTES CT ORB IOM 6 05 08 ION 3M ORBIT...

Page 23: ...P R O C E S S V A L V E S...

Page 24: ...For the most current contact and location information go to www c a m com valvesandmeasurement VALVES MEASUREMENT 3250 Briarpark Drive Suite 300 Houston Texas 77042 USA Toll Free 800 323 9160 CT ORB...

Reviews: