43
Mode #
Output
Description
4 Dual
Continuous
mode
5 Dual
Control
mode
7
Dual
Delayed Transfer mode (only models with Delayed Transfer option)
Command syntax:
MOx
x
Mode of operation [Refer to table above]
The current active mode of operation can be read back from the camera
Command syntax:
MO?
When selecting a new (or the same) operation mode the frame period, image format and integration time for
continuous mode are verified for the selected mode of operation. When the frame period is set for a too small value
it is set to the minimum value possible.
Thereafter the frame period and the integration period is verified. When the integration period is set for a too large
value it is automatically set to the maximum value allowed.
4.2.18 Frame period in continuous mode
In continuous mode [
mode 0,
mode 4] the frame period determines the frame rate.
The frame period is set in units of 10
µ
s.
Frame Rate = 1/Frame Period
Command syntax:
FPx
x
Frame Period in units of 10
µ
s.
Minimum Value = 1
(10
µ
s)
Maximum Value = 4000
(40 ms)
Summary of Contents for ADIMEC-1000m
Page 1: ...ADIMEC 1000m O p e r a t i n g a n d T e c h n i c a l M a n u a l ...
Page 2: ......
Page 6: ......
Page 10: ......
Page 12: ......
Page 16: ...14 Figure 2 1 4 crosshead screws that hold the lensmount front view of the camera ...
Page 18: ...16 ...
Page 39: ...37 Figure 4 2 Test Image ...
Page 41: ...39 Testpattern videolevels 12 bit ...
Page 48: ......
Page 56: ...54 ...
Page 60: ......
Page 62: ......
Page 67: ...65 10 MECHANICAL OUTLINE DRAWING Figure 10 1 Mechanical Outline drawing ...