8
DMX
IT
ALIANO
POLSKI
ESP
AÑOL
FRANCAIS
DEUTSCH
ENGLISH
Settings
Display
= Display lighting
Backlight ON
On permanently
Backlight Off
Deactivates after approximately 30 seconds of inactivity
DMX Fail
= Operating status with
DMX signal fault
Hold
Last DMX command will be retained
Blackout
Activates blackout
DimCurve
= dimmer curve
Linear
Light intensity increases linearly with DMX value
Exp
Light intensity can be finely adjusted at lower DMX values and broadly
adjusted at higher DMX values.
Log
Light intensity can be broadly adjusted at lower DMX values and finely
adjusted at higher DMX values.
S-Curve
Light intensity can be finely adjusted at lower and higher DMX values
and broadly adjusted at medium DMX values.
DimResp.
= Dimmer response
LED
Lamp responds abruptly to changes in DMX value
Halogen
Lamp behaves like a halogen spotlight with soft brightness changes
PWM
= LED PWM frequency
650Hz
Configuration of LED PWM frequency
1530Hz
3600Hz
25000Hz
linear
DMX value
Light intensity
exponential
DMX value
Light intensity
logarithmic
DMX value
Light intensity
S-curve
DMX value
Light intensity
Dimmer curves
DEVICE INFORMATION
Press MENU to access the selection menu for system settings. Using the UP and DOWN controls, select the menu item "Sys info" and confirm
with ENTER. This will take you to the sub-menu for displaying device information. Use the UP and DOWN buttons to select the desired submenu
item and then press ENTER to retrieve the information (see table). Press MENU repeatedly to return to the main display. The main display is
activated automatically if no input is made within approximately 30 seconds.
Sys Info
Temp
= Displays temperature of
LED unit
Temp LED
xxC / xxF
Temp °C/°F
°C (= display in degrees Celsius)
°F (= display in degrees Fahrenheit)
Op.Hours
= Operating time display
Hour xxxh
Displays total operating time in hours
Firmware
= Displays device software
version
Soft Ver
V1.xx