P.
11
- M
a
n
u
a
l co
d
e:
319
V21
EN
V
er
s.
3
0
9
/2
01
4 © C
A
M
E ca
n
ce
lli
a
u
to
m
a
ti
ci
S
.p.
A
. - T
h
e d
a
ta
a
n
d i
n
fo
rm
a
ti
o
n i
n
t
h
is m
a
n
u
a
l a
re su
b
je
ct to c
h
a
n
g
e a
t a
n
y t
im
e w
it
h
o
u
t
p
ri
o
r n
o
ti
ce re
q
u
ir
ed
by Ca
m
e Ca
n
ce
lli
A
u
to
m
a
ti
ci
S
.p.
A
.
ENGLISH
Menu structure
F 1
– “Total stop” Function
F 2
– function assigned to CX input
F 3
– function assigned to CY input
F 5
– Safety test function
F 6
– maintained action function
F 7
– Command mode on 2-7
F 8
– Command mode on 2-3p
F 9
– Obstacle detection function when motor is stopped
F 10
– Warning light function
F 11
– Exclude Encoder function
F 12
– Slow start function
F 13
– Closing thrust function
F 14
– Sensor type selector function
F 16
– Ram head blow function (only for Myto – Amico – Frog J - Stylo RME motors)
F 17
– Lock function (only for Myto – Amico – Frog J - Stylo RME motors)
F 18
– Supplementary light function
F 19
– Automatic closing time
F 20
– Automatic closing time after partial opening
F 21
– pre-flashing time
F 22
– Working time
F 23
– Delay opening time
F 24
– Delay closing time
F 25
– Courtesy light time
F 26
– Ram head blow time (only for Myto – Amico – Frog J - Stylo RME motors)
F 27
– lock time (only for Myto – Amico – Frog J - Stylo RME motors)
F 28
– M1 motor speed adjustment
F 29
– M2 motor speed adjustment
F 30
– M1 motor speed slow-down time adjustment
F 31
– M2 motor speed slow-down time adjustment
F 32
– Additional closing slow down adjustment for M1 and M2 motors (only for Myto and Stylo with straight-arms)
F 33
– Calibration speed adjustment
F 34
– Sensitivity during movement
F 35
– Sensitivity during slow-downs
F 36
– Adjusting partial openings
F 37
– Adjusting the initial slow-down point of the M1 motor when opening
F 38
– Adjusting the initial slow-down point of the M1 motor when closing
F 39
– Adjusting the point the M1 motor begins drawing to the fully open position
F 40
– Adjusting the point the M1 motor begins drawing to the fully closed position
F 41
– Adjusting the initial slow-down point of the M2 motor when opening
F 42
– Adjusting the initial slow-down point of the M2 motor when closing
F 43
– Adjusting the initial drawing to stop point of the M2 motor when opening
F 44
– Adjusting the initial drawing to stop point of the M2 motor when closing
F 45
– Adjusting an additional slow-down point when closing (only for Myto and Stylo RME with straight-arms)
F 46
– Adjusting the number of motors
F 50
– Saving data in memory roll
F 51
– Reading memory roll data
U 1
– Type of command to associate to a user via radio command
U 2
– Cancelling single users
U 3
– Cancelling all user
A 1
– Setting the type of gearmotor
A 2
– Motor tests
A 3
– Gate run calibration
A 4
– Resetting parameters
H 1
– Software version