4 Description

Legend of symbols

 

This symbol shows parts which must be read with care.

 

This symbol means the parts which describe safety issues.

 

This symbol tells you what to tell the end-user.

2.1 Intended use

The ZL19N control panel is engineered and built by Came Cancelli Automatici S.p.A. to command swing gate operators of the FERNI and FROG 
24 V DC series. 

        Any installation and use other than that specified in this manual is forbidden.

3 Reference standards

"IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"

“WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS”

“THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT INDIVIDUALS”

Came Cancelli Automatici employs an ISO 9001 certified quality management system and an  ISO 14001 environmental management 
system. Came entirely engineers and manufactures in Italy.
This product is compliant with: see statement of compliance.

The control panel should be powered by 230 V AC, at 50/60 Hz frequency.

the command devices and accessories are powered by 24V. Warning! The overall power of the connected accessories must not exceed 
40 W overall load.

The control panel features an amperometric device whih constantly controls the motor thrust data. 

When the gate runs in to an obstacle, the amperometric sensor detects a thrust overload and inverts the direction of travel of the gate:

- it reopens it when it is closing

(1)

;

- it recloses it when it is opening.

Warning: if it intervenes when the gate is within 5 cm of the closing or opening strike, it stops its movement (see also OP TIME trimmer 
adjusting on p. 11).

(1) 

Warning: in this case, after 3 consecutive obstacle detections, the gate stops when opening and automatic closing is excluded;for 

movement to resume press the command button or use the transmitter.

The transformers feature a protection that allows the gate leaves to stay open even incase of heat overload.The gate closes only  when 
the temperature returns below the overload limit.

All connections are protected by quick fuses, see table.

The card provides and controls the following functions:

- automatic closing;
- Prefl ashing by the fl ashing light;
- ramming action when closing or opening to ease the release of the electro lock.

Apposte trimmers and faston adjust:
 

- the travel and slowdown speed.

 

- the working time for automatic closing;

 

- the M2 gearmotor closing delay;

 

- the detection sensitivity of the amperometric device, separately from the travel and for the slowdown.

 

Summary of Contents for ZL19N

Page 1: ...English EN Z CONTROL PANELS INSTALLATION MANUAL ZL19N CONTROL PANEL FOR 24V GEARMOTORS 319U33EN...

Page 2: ...the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features an amperometric device whih c...

Page 3: ...ABS container protection rating IP54 working temperature 20 55 C You can also connect gate open warning lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outa...

Page 4: ...ation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Preliminary checks Tr...

Page 5: ...ecure the base of the panel in a safe area yes max 6 mm Head with to 5 3 Anchoring and installing the box Perforate the marked holes and insert the cable glands with corrugated tubes for the electrica...

Page 6: ...e changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections brown brown blue 2 FROG 24 V motors 1 FROG 24 V motor 2 FERNI...

Page 7: ...60 Hz frequency Accessories power source Lighting and warning devices Gate open warning light Contact rated for 24 V 3 W Max Warns of open gate position turns off when gate is closed Flashing light co...

Page 8: ...r safety devices like photocells sensitive edges and other devices that comply with EN 12978 regulations While the gate is closing opening the contact will invert movement until it is fully openend If...

Page 9: ...ECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10 6 1 Electrical connection for photocells functionalities test Stop b...

Page 10: ...2 1 2 3 4 ON 5 6 7 8 9 10 CH1 CH2 RA2 RC2 C FA1 FC1 C FA2 FC2 C RA1 RC1 C TERMICO 3P 7 C1 C3 1 2 3 ENGLISH P 10 10 Manual code 319U33 319U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The dat...

Page 11: ...djusted to between 2 and 120 seconds DELAY 2M Adjusting the M2 waiting time for each closing The waiting time can be adjusted to between 1 and 15 seconds Warning minimum sensitivity maximum power Afte...

Page 12: ...M 433 92 AF43TW TWIN KeyBlock AM 433 92 AF43SR ATOMO AM 40 685 AF40 TOUCH AM 863 35 AF868 TOP 9 Activating the radio command Connect the antenna cable to the terminals Antenna Radio frequency card Pos...

Page 13: ...U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify...

Page 14: ...ED ashes ON and OFF 2 Press the button on the transmitter to be memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Page 15: ...id waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially auth...

Page 16: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11...

Reviews: