4 Description
Legend of symbols
This symbol shows parts which must be read with care.
This symbol means the parts which describe safety issues.
This symbol tells you what to tell the end-user.
2.1 Intended use
The ZL19N control panel is engineered and built by Came Cancelli Automatici S.p.A. to command swing gate operators of the FERNI and FROG
24 V DC series.
Any installation and use other than that specified in this manual is forbidden.
3 Reference standards
"IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"
“WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS”
“THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT INDIVIDUALS”
Came Cancelli Automatici employs an ISO 9001 certified quality management system and an ISO 14001 environmental management
system. Came entirely engineers and manufactures in Italy.
This product is compliant with: see statement of compliance.
The control panel should be powered by 230 V AC, at 50/60 Hz frequency.
the command devices and accessories are powered by 24V. Warning! The overall power of the connected accessories must not exceed
40 W overall load.
The control panel features an amperometric device whih constantly controls the motor thrust data.
When the gate runs in to an obstacle, the amperometric sensor detects a thrust overload and inverts the direction of travel of the gate:
- it reopens it when it is closing
(1)
;
- it recloses it when it is opening.
Warning: if it intervenes when the gate is within 5 cm of the closing or opening strike, it stops its movement (see also OP TIME trimmer
adjusting on p. 11).
(1)
Warning: in this case, after 3 consecutive obstacle detections, the gate stops when opening and automatic closing is excluded;for
movement to resume press the command button or use the transmitter.
The transformers feature a protection that allows the gate leaves to stay open even incase of heat overload.The gate closes only when
the temperature returns below the overload limit.
All connections are protected by quick fuses, see table.
The card provides and controls the following functions:
- automatic closing;
- Prefl ashing by the fl ashing light;
- ramming action when closing or opening to ease the release of the electro lock.
Apposte trimmers and faston adjust:
- the travel and slowdown speed.
- the working time for automatic closing;
- the M2 gearmotor closing delay;
- the detection sensitivity of the amperometric device, separately from the travel and for the slowdown.