8 Settings

- END ADJ/SENS. 

 

* End adjustement of amperometric sensor during travel:min/max.

- AMP SENS. 

* Adusts the amperometric sensitivity which controls the force developed by the motor during 
movement; if the force exceeds the adjusted level, the system intervenes and inverts the direction of 
travel.

- SLOWDOWN/AMP SENS 

* Adusts the amperometric sensitivity which controls the force developed by the motor during 
movement; if the force exceeds the adjusted level, the system intervenes and inverts the direction of 
travel.

- OP TIME    

Adjusts the closing strike zone.

- ACT 

 

Adjusts the waiting time when open.Once this time elapses, automatic closing is triggered.The waiting 
time can be adjusted to between 2 and 120 seconds.

- DELAY 2M  

Adjusting the M2 waiting time for each closing.The waiting time can be adjusted to between 1 and 15 
seconds.

* Warning!: minimum sensitivity = maximum power

After setting the slowdowns (fi g. 3) with the "micro-switch adjusting" illustrated in the gearmotor manual ...

... prepare a 60 x 30 mm template and keep it rested against one of the two strike plates, as shown in fi g. 1 (you can adjust it either on 
the  closing  or  opening  strike  plates).          

Activate the gate - with a command button or with the transmitter - and turn the OP TIME trimmer clockwise until the gatge leaf inverts 
its direction of travel the moment it touches the obstacle/template.  

Then turn the template from the short side (fi g. 2) and check that the gate lead stops by touching the obstacle/template.Otherwise turn 
the trimmer counter-clockwise.

If you have a two-leaf gate, carry out the procedure on both gate leaves.

Adjusting the closing strike zone

fi g. 1

fi g. 3

  

A =  Eff ective zone of the amperometric sensor 

with movement inversion 

B =  Normal speed travel zone
C =  Decelerated speed travel zone
D = Eff ective zone of the amperometric sensor 

with  movement  stop        

E =  Closing and opening strike plates

fi g. 2

Summary of Contents for ZL19N

Page 1: ...English EN Z CONTROL PANELS INSTALLATION MANUAL ZL19N CONTROL PANEL FOR 24V GEARMOTORS 319U33EN...

Page 2: ...the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features an amperometric device whih c...

Page 3: ...ABS container protection rating IP54 working temperature 20 55 C You can also connect gate open warning lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outa...

Page 4: ...ation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Preliminary checks Tr...

Page 5: ...ecure the base of the panel in a safe area yes max 6 mm Head with to 5 3 Anchoring and installing the box Perforate the marked holes and insert the cable glands with corrugated tubes for the electrica...

Page 6: ...e changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections brown brown blue 2 FROG 24 V motors 1 FROG 24 V motor 2 FERNI...

Page 7: ...60 Hz frequency Accessories power source Lighting and warning devices Gate open warning light Contact rated for 24 V 3 W Max Warns of open gate position turns off when gate is closed Flashing light co...

Page 8: ...r safety devices like photocells sensitive edges and other devices that comply with EN 12978 regulations While the gate is closing opening the contact will invert movement until it is fully openend If...

Page 9: ...ECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10 6 1 Electrical connection for photocells functionalities test Stop b...

Page 10: ...2 1 2 3 4 ON 5 6 7 8 9 10 CH1 CH2 RA2 RC2 C FA1 FC1 C FA2 FC2 C RA1 RC1 C TERMICO 3P 7 C1 C3 1 2 3 ENGLISH P 10 10 Manual code 319U33 319U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The dat...

Page 11: ...djusted to between 2 and 120 seconds DELAY 2M Adjusting the M2 waiting time for each closing The waiting time can be adjusted to between 1 and 15 seconds Warning minimum sensitivity maximum power Afte...

Page 12: ...M 433 92 AF43TW TWIN KeyBlock AM 433 92 AF43SR ATOMO AM 40 685 AF40 TOUCH AM 863 35 AF868 TOP 9 Activating the radio command Connect the antenna cable to the terminals Antenna Radio frequency card Pos...

Page 13: ...U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify...

Page 14: ...ED ashes ON and OFF 2 Press the button on the transmitter to be memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Page 15: ...id waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially auth...

Page 16: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11...

Reviews: