background image

ZL180

EN 60335-1   

EN 61000-6-2

EN 60335-2-103  

EN 61000-6-3

EN 13241-1

Pa

g.

 

2

2

22

  - M

an

u

al c

od

e: 

3

1

9

U

17

31

9

U

17

 ve

r.

 

1

2

 
12

 

04/

2

0

10

9  © C

A

M

E c

an

ce

lli auto

m

ati

ci s.p.a. - T

h

e d

ata a

n

d i

nf

or

m

ati

on r

ep

orte

d i

n th

is i

n

sta

lla

tio

n m

an

u

al a

re s

u

sc

ep

tib

le to 

ch

an

g

e at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on o

n C

A

M

E c

an

ce

lli auto

m

ati

ci

 s.p.a. to n

otify u

se

rs.

ENGLISH

12 Phasing out and disposal

Our products are made with different types of materials. The majority of these (aluminium, plastic, iron and electrical cables) are 

part of the solid urban waste category. They can be recycled through licensed waste disposal plants.

Other components (electronic cards, remote control batteries, etc.) constitute hazardous waste. Thus, they are to be removed and 

delivered to licensed fi rms that specialise in their proper disposal.

EC DECLARATION OF CONFORMITY

Pursuant to the Low Voltage Directive 2006/95/CE

 

CAME Cancelli Automatici S.p.A.

 

via Martiri della Libertà, 15

 

31030 Dosson di Casier - Treviso - ITALY

 

tel (+39) 0422 4940 - fax (+39) 0422 4941

 

internet: www.came.it - e-mail: [email protected] 

Declares under its own responsibility that the equipments for automatic garage doors and gates listed below:

CONTROL PANELS FOR SWING GATES

… comply with the National Law related to the following European Directives and to the applicable parts of the 
following Standards.

2006/95/EC

 

L

OW

 V

OLTAGE

 D

IRECTIVE

2004/108/EC

  E

LECTROMAGNETIC

 C

OMPATIBILITY

 D

IRECTIVE

13 Conformity declaration

MANGING DIRECTOR

Mr. Gianni Michielan

Codice di riferimento per richiedere una copia conforme all’originale: 

DDF L EN Z002f

IMPORTANT WARNING!

Do not use the equipment specifi ed here above, before completing the full installation

in full compilance to the Low Voltage Directive 2006/95/CE

Summary of Contents for ZL180 SERIES

Page 1: ...ZL180 SERIES INSTALLATION MANUAL ZL180 CONTROL PANEL FOR 24V OPERATORS English EN...

Page 2: ...nd controls the following functions automatic closing after an open command pre flashing by the motion indicator obstacle detection when gate is still in any position continual monitoring of photocell...

Page 3: ...g on the machinery cut off the main power supply and disconnect any emergency batteries 1 Transformer 2 Control unit fuse 3 Trimmers see page 9 4 Buttons for memorising the radio code 5 Plug for the r...

Page 4: ...tted with extra insulation as compared to the other conductive parts inside Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanica...

Page 5: ...ctual power draw from the connected devices and according to the CEI EN 60204 1 standards For connections that require several sequential loads the sizes given on the table must be re evaluated based...

Page 6: ...e following accessories 24 V AC normally alternated power 24 V AC continuous power when the emergency batteries are in operation Overall power allowed 34 W Power supply 230 V AC 50 60 Hz 6 4 POWER SUP...

Page 7: ...24V DC gearmotor featuring delayed action on opening M1 Left hand installed inside view Standard installation A3024N A5024N gearmotors RA RA Opening speed blocker microswitch RC RC Closing speed redu...

Page 8: ...k F7024N gearmotors RA RA Microswitch Opening programmable RA RA Opening speed blocker microswitch RC RC Closing speed reduction microswitch M red N black F7024N gearmotors 24V DC gearmotor featuring...

Page 9: ...gearmotors 2 leaved gates With only one gearmotor one leaved gates M2 gearmotor do the following he following a a Set Set dip switches 4 and 6 to ON dip switches 4 and 6 to ON and dip switches 1 2 3 5...

Page 10: ...Mode 2 Does not allow connection of an indicator lamp on 10 5 after connection it a a Set Set dip switches 2 and 6 to ON dip switches 2 and 6 to ON and dip switches 1 3 4 5 to OFF b b c c d d continu...

Page 11: ...uring closing N C socket Input for safety devices such as photocells sensitive edges and other EN 12978 compliant devices When gate leaves are closing opening the contact causes reversal until total o...

Page 12: ...as just made see selecting functions dips 2 and 3 Key selector and or partial opening button N O socket Opening of one gate leaf to allow pedestrian passage 6 7 COMMAND DEVICES At each opening and clo...

Page 13: ...g gate closing the gate motion is inverted until total opening is reached connect the safety device to terminals 2 C1 sif not used set DIP switch to ON 8 OFF Partial stop stops gate when an obstacle i...

Page 14: ...signed to the opening endstop see paragraph 6 4 page 7 the adjustment settings will be the following Opening Stop default function CLOSING ENDSTOP ATI gearmotors However if it intervenes activating th...

Page 15: ...ch above Upper cam Lower cam Lower cam fixing and locking release screw Upper cam fixing and locking release screws ENDSTOP ASSEMBLY FAST gearmotors WARNING Make sure you have inverted the M N connect...

Page 16: ...is released Secure the cam by tightening the lateral screws N B The closing endstop can be adjusted after setting the opening microswitch Warning the upper cam of the operator s endstop assembly is c...

Page 17: ...time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH OPENING ENDSTOP RIGHTHAND GEARMOTOR INSIDE VIEW Remove the screws from the upper cam and turn it upsidedown Releas...

Page 18: ...ral screws Release the gearmotor and fully close the gate leaf N B Always first adjust the opening endstop and then the closing endstop Warning the upper cam of the operator s endstop assembly is cali...

Page 19: ...cells connected to REOPEN DURING CLOSING or non operation of the same C3 Yellow LED Normally off When it is on and with the PROG LED blinking it warns of objects detected by the photocells connected t...

Page 20: ...O AT01 AT02 AT04 CAME CAME CAME TWIN TWIN2 TWIN4 Pag 20 20 Manual code 319U17 319U17 ver 12 12 04 20109 CAME cancelli automatici s p a The data and information reported in this installation manual are...

Page 21: ...The LED flashes 2 Press the transmitter button you wish to memorise The LED will stay on to show memorisation has been successful LED flashing LED on 11 4 MEMORISATION CH1 Channel for direct command t...

Page 22: ...ecialise in their proper disposal EC DECLARATION OF CONFORMITY Pursuant to the Low Voltage Directive 2006 95 CE CAME Cancelli Automatici S p A via Martiri della Libert 15 31030 Dosson di Casier Trevis...

Page 23: ...i automatici s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH...

Page 24: ...ottingham Nottingham Ng10 5bp 44 115 9210430 44 115 9210431 RUSSIA CAME Rus CAME Rus Umc Rus Llc Umc Rus Llc Ul Otradnaya D 2b Str 2 of ce 219 127273 Moscow Moscow 7 495 739 00 69 7 495 739 00 69 ext...

Reviews: