P
age
14
- Manual
FA01768-EN
- 07/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device
Output
Power supply (V)
Power (W)
Accessories
10 - 11
24 AC
40
Additional light
10 - E
24 AC
15
Flashing beacon
10 - E
24 AC
15
Operator status warning light
10 - 5
24 AC
3
The output delivers 24 V DC when the batteries start operating, if they are installed.
Command and control devices
1
STOP button (NC contact)
This stops the operator and excludes automatic closing. Use a control device to resume movement.
When the contact is being used, it must be activated during programming.
See the [F1 – Total stop] function.
2
Control device (NO contact)
Open command
Partial Opening command
Partial Opening or Pedestrian command
When the [F6 – Hold-to-run] function is active, a control device must be set to OPEN.
See the [F8 – 2-3P command] function.
3
Control device (NO contact)
Step-by-step command
Sequential command
See the [F7 – 2-7 command] function
4
Card reader
5
Transponder selector switch
6
Keypad selector
7
Antenna with RG58 cable
If the chosen signalling device can be fitted with an antenna, use the terminal shown to connect it.
A
B
S1 GND
Summary of Contents for VER10DMS
Page 1: ...VER10DMS VER13DMS FA01768M04 IT Italiano EN English FR Français RU Русский ...
Page 2: ......
Page 29: ...Garage door operators VER10DMS VER13DMS INSTALLATION MANUAL FA01768 EN EN English ...
Page 30: ......
Page 58: ......
Page 85: ...Автоматика для гаражных ворот VER10DMS VER13DMS РУКОВОДСТВО ПО МОНТАЖУ FA01768 RU RU Русский ...
Page 86: ......