background image

p. 

2

6

26

 - M

an

u

al

 

F

A

0

0

0

4

5

-E

N

F

A

000

4

5

-E

N

 v.

 

22

 - 0

9

/2

0

1

6 - © C

am

e S

.p.

A

. - T

h

e c

onte

nt

s o

f th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed

, at a

ny ti

m

e, a

n

d w

ith

ou

t n

oti

ce

.

Date

Notes Signature

Fitter's stamp

Name of operator

Job performed on (date)

Technician's signature

Requester's signature

Job performed

 ___________________________________________________________________________

______________________________________________________________________________________
______________________________________________________________________________

Extraordinary maintenance

⚠ 

The following table is for logging any extraordinary maintenance jobs, repairs and improvements performed by 

specialized contractors.
N.B.: Any extraordinary maintenance jobs must be done only by specialized technicians.

Extraordinary maintenance log

a

MAINTENANCE

Periodic maintenance

 

Before doing any maintenance, cut off the mains power supply, to prevent any hazardous situations 

resulting from the door's unexpected movement.

Periodic maintenance log kept by users (every six months)

Fitter's stamp

Name of operator

Job performed on (date)

Technician's signature

Requester's signature

Job performed

 ___________________________________________________________________________

______________________________________________________________________________________
______________________________________________________________________________

Summary of Contents for VER10

Page 1: ...INSTALLATION MANUAL VER10 VER12 FA00045 EN OPERATORS FOR GARAGE DOORS English EN ...

Page 2: ...N MAY RESULT IN SERIOUS BODILY INJURY INSTALLING SUITABLY SECTION OFF AND DEMARCATE THE ENTIRE INSTALLATION SITE TO PREVENT UNAUTHORIZED PERSONS FROM ENTERING THE AREA ESPECIALLY MINORS AND CHILDREN BE CAREFUL WHEN HANDLING OPERATORS THAT WEIGH OVER 20 KG IF NEED BE USE PROPER SAFETY HOISTING EQUIPMENT ALL OPENING COMMANDS THAT IS BUTTONS BUTTON SWITCHES MAGNETIC READERS AND SO ON MUST BE INSTALLE...

Page 3: ... MAY RUIN THE DEVICES IF REPAIRS OR MODIFICATIONS ARE REQUIRED TO THE SYSTEM RELEASE THE OPERATOR AND DO NOT USE IT UNTIL SAFETY CONDITIONS HAVE BEEN RESTORED CUT OFF THE POWER SUPPLY BEFORE RELEASING THE OPERATOR FOR MANUAL OPENINGS AND BEFORE ANY OTHER OPERATION TO PREVENT ANY RESULTING HAZARDS SEE INSTRUCTIONS IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR AUTHO...

Page 4: ...signed to power overhead garage doors in residential and apartment block settings Any installation and or use other than that specified in this manual is forbidden Limits to use Type VER10 VER12 Door s max surface area m2 18 21 Counter weighted overhead door s max weight m 2 40 2 40 Maximum height of spring balanced overhead doors m 3 25 3 25 Maximum height of door m 3 20 3 20 Technical data Type ...

Page 5: ...ver 2 Gearmotor 3 Transformer 4 Control board 5 Transmission arm for the VER10 6 Transmission arm for the VER12 7 Door fastening brace 8 Guide fastening brace 9 Ceiling fastening brace 10 Cable gland 11 Fastening screws Only for sectional doors Dimensions Description of the traction guide 1 Guide 2 Chain or belt 3 Traction assembly with release lever 4 Mechanical stop 5 Support rods ...

Page 6: ...overhead doors up to 2 75 m in height Sectional doors up to 2 70 m in height 001 001V0687 Chain guide L 3 02 in two pieces Counter balanced overhead doors up to 2 4 m in height Counter balanced overhead doors up to 2 25 m in height Sectional doors up to 2 20 m in height 001V0688 Belt guide T 4 02 m Spring balanced overhead doors up to 3 25 m in height Sectional doors up to 3 20 m in height For sec...

Page 7: ...ny in between point it should hold its position Cable types and minimum thicknesses Connection Cable type Cable length 1 15 m Cable length 15 30 m Control panel power supply 230 V AC H05VV F 3G x 1 5 mm 2 3G x 2 5 mm 2 Flashing light FROR CEI 20 22 CEI EN 50267 2 1 2 x 0 5 mm 2 Photocell transmitters 2 x 0 5 mm 2 Photocell receivers 4 x 0 5 mm 2 Command and safety device 2 x 0 5 mm 2 Antenna RG58 ...

Page 8: ...th double slide guides SECTIONAL DOOR COUNTERBALANCED OVERHEAD DOOR PARTIALLY RETRACTING AND PROTRUDING SPRING BALANCED OVERHEAD DOOR FULLY RETRACTING AND PROTRUDING INSTALLATION The following illustrations are just examples in that the space available for fitting the operator and accessories varies depending on the overall dimensions It is up to the installer to find the most suitable solution As...

Page 9: ... the upper part of the door is between 300 and 600 mm use the V122 transmission arm For protruding overhead garage doors kepp the guide at 20 from the highest opening point Fastening the traction guide The traction guide should be fastened at the center of the door opening using suitable screws Raise the guide and position it horizontally to measure the distance from the ceiling and then fasten it...

Page 10: ...guide and to the ceiling If necessary fit additional support rods Drill the ceiling where the braces will god and fit them to the ceiling using suitable dowels and screws Fitting the transmission arm to the door Position the transmission arm brace to the door s top rail perpendicularly to the traction guide and fasten it using the supplied screws or other suitable screws ...

Page 11: ...al may be changed at any time and without notice Turn the release lever clock wise Move the traction assembly towards the door and fasten the transmission arm using the supplied bolt Fitting the operator to the guide Fasten the operator to the traction guide using the supplied screws The operator can also be fitted laterally ...

Page 12: ...LECTRICAL CONNECTIONS FUSE TABLE Motor A 8 Accessories A 3 15 Control device mA 315 Line fuses A 1 6 LIGHTS LED courtesy lights 24 V E14S W 1 Components 1 Line fuse 2 Motor fuse 3 Accessories fuse 4 Control 5 panel Gearmotor board fuse 6 Transformer 7 Battery housing 8 Transformer connection terminals 9 Gearmotor connection terminals 10 Encoder connection terminals 11 Accessories connection termin...

Page 13: ...er supply 230 V AC 50 60 Hz Terminals for powering up accessories 24 V AC grid powered 230 V 24 V DC when the emergency batteries are operating Overall allowed power 40 W Eyelet end piece for grounding connection Command and control devices Stop button NC contact Enables the door to stop and excludes the automatic closing To resume movement use the control device OPEN STOP CLOSE STOP sequential fu...

Page 14: ...door to invert its movement until it is completely open If a device is connected remove the bridge Signaling devices Flashing light connecting contact rated for 24 V AC 25 W max It flashes during the door s opening and closing phases Selecting DIP switches DIP SWITCH Description of functions 1 ON It activates the opening and closing limit switch setting procedure and the delayed opening setting pr...

Page 15: ...ction of travel Automatic Closing Time Sets the open door s waiting time Once this time elapses a closing maneuver is automatically performed The time can be set between 0 and 120 seconds Sets the time to a minimum and excludes AUTOMATIC CLOSING Sensitivity during closing Adjusts the amperometric sensitivity that controls the force exerted by the motor during closing if the exerted force is greate...

Page 16: ...l stop Release the operator and completely open the door Encoder operation Obstruction detection when CLOSING The door inverts its travel direction and reopens After three consecutive inversions the door stays open and excludes the automatic opening To reclose the door press a control button or use the transmitter Obstruction detection when OPENING The door recloses ...

Page 17: ... any time and without notice Position the mechanical stop against the traction assembly and fasten it Mechanical stop Traction assembly Manually close the door until it latches shut Establishing the closing and opening limit switch points Set DIP switch 1 to ON the programming LED will flash Press the OP CL button until the door reaches the closing strike plate ...

Page 18: ...C RADIO A C T SLOW SENS CL SENS OP SENS R FUSE 2 1 ON F OPEN OP CL AF 26V 17V 0V M N E ENC RADIO A C T SLOW SENS p 18 18 Manual FA00045 EN FA00045 EN v 2 2 09 2016 Came S p A The contents of this manual may be changed at any time and without notice Press the ENC RADIO button to memorize the closing point Press the OPEN button until the door reaches its completely open point Press the ENC RADIO but...

Page 19: ...ut notice Programming the partial opening When the door is fully closed set DIP switch 2 to ON the LED will flash Press the OPEN button until the door reaches the wanted opening position Press ENC RADIO to memorize the partial opening Reset DIP switch 2 to OFF Programming the slow start with door open max 50 of the door travel Before programming deactivate the automatic closing by setting the trimm...

Page 20: ...tton until the door reaches the desired end slow down point Press the ENC RADIO button until the LED stays on to signal that memorization is now complete Reset DIP switch 1 to OFF Programming the closing slow down min 600 mm from the final closing strike or max 50 of the door travel When the door is fully closed press the ENC RADIO button the LED will flash rapidly Set DIP switch 2 to ON the LED tu...

Page 21: ...s manual may be changed at any time and without notice Press the OPEN button until the door reaches the desired closing slow down start point PPress the ENC RADIO button until the LED stays on to signal that memorization is now complete Reset DIP switch 2 to OFF ACTIVATING THE RADIO CONTROL Before fitting the AF card you MUST CUT OFF THE MAIN POWER SUPPLY and remove any emergency batteries Connect...

Page 22: ... for the 2 7 sequential command Press the ENC RADIO button on the control board The warning LED flashes Press the button on the transmitter you wish to memorize The LED stays on to indicate that memorization has been successful AF card Activating for the 2 3P partial opening command Keep the ENC RADIO button pressed and then press the OP CL button The LED will flash Press the button on the transmi...

Page 23: ...at any time and without notice Deleting all of the memorized transmitters Set DIP switch 1 and DIP switch 2 to ON the warning LED will start flashing Press the ENC RADIO button for 5 seconds the LED starts flashing quickly and stays on to signal that deletion is complete Reset the DIP switches to OFF FINAL OPERATIONS Do the final operation only once the connections are complete and the system is star...

Page 24: ...d without notice RELEASING THE OPERATOR This procedure must be done with the mains power cut off Manually releasing the operator can cause the door to move unexpectedly if the door has any mechanical issues or is unbalanced RELEASING Turn the release lever clock wise LOCKING Manually close the door until it latches shut ...

Page 25: ...inate all mechanical friction Check the door balancing Check the tautness of the belt chain Only one transmitter works Enter or duplicate the same code in all the transmitters The photocell is not working The N C safety contact 2 C1 is open Check proper functioning of the photocell The PROGRAMMING LED flashes rapidly The N C safety contact 2 C1 is open The Encoder doesn t work cut off the power to...

Page 26: ...dinary maintenance jobs repairs and improvements performed by specialized contractors N B Any extraordinary maintenance jobs must be done only by specialized technicians Extraordinary maintenance loga MAINTENANCE Periodic maintenance Before doing any maintenance cut off the mains power supply to prevent any hazardous situations resulting from the door s unexpected movement Periodic maintenance log...

Page 27: ... waste They can be recycled by separating them before dumping at authorized city plants Whereas other components control boards batteries transmitters and so on may contain hazardous pollutants These must therefore be disposed of by authorized certified professional services Before disposing it is always advisable to check with the specific laws that apply in your area DO NOT DISPOSE OF IN NATURE ...

Page 28: ... Dosson di Casier Treviso Treviso Italy 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 www came com www came com English Manual FA00045 EN v 2 09 2016 Came S p A The contents of this manual may change at any time and without notice ...

Reviews: