Technical features
Type
VA/200.
01
Supply voltage
220-230 VAC
50/60 Hz.
Self-resetting electric safety switch
Rated power
60VA.
Output voltages:
17.5V DC stabilised (0.9A for continuous service and 0.6A for intermittent service) for
monitor, entry panel and accessories.
• 12V DC stabilised (400mA for continuous service)
• 12V DC (0.5A for intermittent service) for electrical door lock.
Two differential call note generators, controlling up to 3 internal units.
Installation activation
time
30 s. If the handset is lifted during this interval, the activation
time is extended by 30 to a maximum of 90 s (adjustable).
Electrical door lock
activation time
with time interval adjustment of 1 to 15 s. Compatible with
both direct and alternate current-operated electrical door lock
(12V DC, AC, 1A).
Stair light actuator
output
type VLS/101.
Working temperature
range
from 0 °C to +35 °C.
Dimensions
The power supplier can be installed without terminal covers into boxes provided with DIN rail
(EN 50022).Dimensions are shown in fig.
B
❶
.
Or it can be wall-mounted using the DIN rail provided, applying as necessary the terminal covers and
plugs provided.
Dimensions are shown in fig.
B
❷
.
☞
The unit is protected against overloads and short-circuits by a self-resetting thermal
switch, inserted on the primary of the power supply transformer. Once the switch trips,
operation is resumed automatically once the temperature of the transformer drops back below
85 °C.
Make sure the cause of the switch tripping is eliminated.