Preliminary checks

Tools and materials

 

The following is necessary before installing the turnstile:

•  If necessary, provide the corrugated tubing required for the passage of electrical cables;
•  Provide a suitable omnipolar disconnector device, with a maximum of 3 mm between the contacts, to disconnect the power supply;
•  Prepare suitable piping and ducts for routing the electrical cables, ensuring protection against mechanical damage;

• 

 Make sure that any connections within the container (made to ensure the continuity of the protection circuit) are fitted with additional insulation compared to 

the other internal conductor parts;

Types of cables and minimum thicknesses

 If the cables differ in length from what is shown in the table, the cable cross-section is determined according to the actual current draw of the devices connected 

and according to the provisions of the IEC EN 60204-1 standard.
For connections that require several, sequential loads, the sizes listed in the table must be re-evaluated based on actual power draw and distances. When connecting 
products that are not specified in this manual, please refer to the documentation provided with said products.

Connection

Cable type

Cable length

1 < 10 m

Cable length

10 < 20 m 

Cable length

20 < 30 m

230 V power supply control panel

FROR CEI 20-22 

IEC EN 

50267-2-1

3G x 1.5 mm

2

3G x 1.5 mm

2

3G x 1.5 mm

2

Accessory power supply

2 x 0.5 mm

2

2 x 0.5 mm

2

2 x 1 mm

2

Control and safety devices

2 x 0.5 mm

2

2 x 0.5 mm

2

2 x 0.5 mm

2

Make sure you have all the tools and materials needed for the installation at hand to work in 
total safety and compliance with current standards and regulations. The figure shows some 
examples of installer’s tools.

INSTALLATION

The following illustrations are only examples, given that the space for securing the turnstile and accessories varies depending on the overall dimensions. The 
installation technician is responsible for choosing the most suitable solution.

The turnstile must be mounted by two people. Transport and lift using appropriate lifting equipment.

 Risk of tipping over! Do not lean on the turnstile until it is fully secured.

Preparing the turnstile

Lift 

 and extract them

.

Remove the casing by unscrewing the fixing screws.

GENERAL INSTRUCTIONS FOR INSTALLATION

 

Installation must be carried out by qualified and experienced personnel in compliance with applicable regulations.

Summary of Contents for TWISTER LIGHT PSBPS07N

Page 1: ...INSTALLATION MANUAL English EN 119G3782EN TRIPOD TURNSTILES TWISTER LIGHT PSBPS07N PSBPS08 PSBPS09 PSBPS10 ...

Page 2: ... identification data must be clearly visible Before connecting the turnstile to the power supply make sure the identification data corresponds to the mains data The turnstile must be connected to an effective compliant earthing system The manufacturer disclaims any liability for the use of non original products this also results in the invalidation of the warranty All hold to run commands must be pl...

Page 3: ...nst climbing over Automatic tripod release in the event of a blackout 001PSBPS10 AISI 304 steel bidirectional electromechanical turnstile with scotch brite finish complete with control board hydraulic damper and LED arrow indicators lights plus arm drop system Automatic tripod release in the event of a blackout Technical data Model PSBPS07N PSBPS08 PSBPS09 PSBPS10 Protection rating IP 44 Control p...

Page 4: ... and washers for fixing the legs 13 Screw for fixing the casing 1 Legs 2 Tripod 3 Steel housing 4 Casing 5 Casing cover 6 Top cover 7 LED arrow indicatorss 8 Mechanism 9 TOR100A control panel 10 Cover lock 11 Screws and washers for fixing the legs 12 Screw for fixing the casing 13 Photocell holder crosspiece 14 Security photocells 15 Protection against climbing over sensors 1 Legs 2 Tripod 3 Sheet...

Page 5: ...time without prior notice by CAME Cancelli Automatici S p a Dimensions Example of a system 1 Tripod turnstile 2 Arrow indicators 3 Junction box 4 Barrier Examples of use Standard installation Wall flanking installation Multiple installation A turnstile regulated exit should not be considered an emergency exit Always provide an exit for emergency situations and for the physically impaired Recommend...

Page 6: ...e table must be re evaluated based on actual power draw and distances When connecting products that are not specified in this manual please refer to the documentation provided with said products Connection Cable type Cable length 1 10 m Cable length 10 20 m Cable length 20 30 m 230 V power supply control panel FROR CEI 20 22 IEC EN 50267 2 1 3G x 1 5 mm 2 3G x 1 5 mm 2 3G x 1 5 mm 2 Accessory powe...

Page 7: ... screws M10x60 and flat head washers Drill the marked holes and insert the dowels into them The floor on which the turnstile is fixed must be perfectly level Securing the turnstile The turnstile ancoring spot depends on the size of the gap and the possible accessories to be connected Once you have determined the location use a pencil to mark the drill holes according to the dimensions indicated mm...

Page 8: ...d L2T Black Replace the 1 6 A line fuse with a 3 15 A unit Must be performed by the installer ELECTRICAL CONNECTIONS Description of the components 1 Transformer 2 Transformer terminal block 3 Accessory fuse 4 Transit sensor terminal block 5 Line fuse 6 Power supply terminal block 7 Control ans safety device terminal block 8 Electric lock terminal block 9 Arrow indicators terminal block PSBPS10 PSB...

Page 9: ...without prior notice by CAME Cancelli Automatici S p a Devices already connected all models White Brown Green Transit sensor White Red 230 V AC White Black 120 V AC Blue Blue Transformer Red Red Red Red Electric lock Photocell Photocell Photocells PSBPS09 PSBPS09 Sensor Sensor Protection against climbing over sensors PSBPS09 PSBPS09 Buzzer PSBPS09 PSBPS09 Devices to be connected Arrow indicatorss ...

Page 10: ...llows clockwise unlocking of tripod The tripod will lock automatically after a fixed time of 10 s Release button N C contact Allows the tripod to be unlocked for rotation in both directions Terminal block for 24 V AC powering of accessories with maximum current and power draw of 250 mA and 35 W respectively FINAL OPERATIONS Wait 10 seconds before performing any operation after connecting the turnst...

Page 11: ... by acting on the tripod and while screwing unscrewing the damper adjust braking force of the rotating mechanism it must smoothly reach the end run during slowdown Make sure that slowdown is as expected for both clockwise and anti clockwise rotation Lock the hydraulic damper by tightening the bolt ADJUSTING THE HYDRAULIC DAMPER Put the cover on and close the lock with the key MAINTENANCE Before an...

Page 12: ...n engaged Invite the person to stop leaning on the arm and try again Contact service Check the validity of the release command The tripod does not slow down at end run The hydraulic damper is not functioning properly Adjust the damper The turnstile is unlocked after passage The transit sensor is incorrectly positioned The transit sensor is damaged Check the position of the transit sensor Contact s...

Reviews: