background image

Pa

g

2

  - M

an

u

al

 c

od

e: 

11

9

G

3

7

8

2

E

N

11

9

G

3

7

8

2

E

N

 ve

r.

 

1

  

1  

0

1/

2

0

14  © C

A

M

E

 c

an

ce

lli

 auto

m

ati

ci

 S

.p.

A

. - T

h

e d

ata a

n

d i

n

fo

rm

ati

on p

rovi

d

ed

 in

 th

is

 m

an

u

al

 a

re s

u

b

je

ct to c

h

an

g

e at a

ny ti

m

e w

ith

ou

t p

ri

or n

oti

ce

 by C

A

M

E

 C

an

ce

lli

 A

u

to

m

ati

ci

 S

.p.a.

Emergency button

CAUTION!

important personal safety instructions:

READ CAREFULLY!

Foreword

• This product should only be used for the purpose for which it was explicitly 
designed. Any other use is considered dangerous. CAME Cancelli Automatici 
S.p.A. will not be held liable for damage caused by improper, incorrect or 
unreasonable use. • The safety of the product, and therefore its proper 
installation, depends on total compliance with the technical specifi cations and 
installation procedures, as well as with rules regarding safety and use, expressly 
mentioned in the technical documentation for the products themselves. • Keep 
these warnings together with the installation and operation manuals for the 
operator system components.

Before installing

(preliminary check: in case of a negative outcome, do not proceed until you 
have complied with the safety requirements)

• Installation and testing must only be performed by qualifi ed personnel • 
Cable routing, installation, connection and testing must be carried out to 
the highest levels of workmanship in accordance with applicable laws and 
regulations • Before starting any operation, read all the instructions carefully; 
incorrect installation can be dangerous and harm persons or property • Check 
that the operator is in good mechanical condition, balanced and aligned, and 
that it opens and closes properly. If needed, also install suitable guards or use 
appropriate additional safety sensors • If the operator will be installed at a 
height of less than 2.5 m from the ground or other access level, check whether 
you will need any protections and/or warnings • Ensure that opening the 
turnstile does not create a dangerous situation • Do not mount the operator 
upside down or onto any elements that may fold under its weight. If needed, 
add suitable reinforcements at the points where it is secured • Do not install on 
ground that is not level • Check that any lawn watering devices will not wet the 
operator from the bottom up.

Installation

• Carefully section off  the entire site to prevent unauthorised access, especially 
by minors and children • Be careful when handling operators that weigh more 
than 20 kg. In such cases, use proper weight handling safety equipment • 
CE safety devices (photocells, platforms, sensitive edges, emergency buttons 
etc.) must be installed in compliance with applicable legislation and according 
to the highest standards of workmanship, bearing in mind the environment, 
the type of service required and the operating forces applied to the moving 
turnstiles. Points where there is a risk of crushing, shearing or dragging must 
be protected using suitable sensors • End users must be informed of any 
residual risks by means of special pictograms as envisaged by legislation • 
All opening commands (buttons, key selectors, magnetic readers etc.) must be 
installed at least 1.85 m from the perimeter of the area of turnstile movement, 
or where they cannot be reached from outside through the turnstile. Also, 
the direct commands (buttons, touch commands etc.) must be installed at a 
height of at least 1.5 m and must not be accessible to the public • The turnstile 
identifi cation data must be clearly visible • Before connecting the turnstile to 
the power supply, make sure the identifi cation data corresponds to the mains 
data • The turnstile must be connected to an eff ective, compliant earthing 
system • The manufacturer disclaims any liability for the use of non-original 
products; this also results in the invalidation of the warranty • All ‘hold-to-
run’ commands must be placed where the moving turnstile, transit areas and 
driveways are completely visible • Before delivery to the user, check that the 
system complies with the EN 12453 and EN 12445 standards (impact tests), 
check that the operator has been properly adjusted and that the safety and 
protective devices work correctly • As appropriate and in a visible position, affi

  x 

warning symbols.

Special instructions and advice for users

• Keep the turnstile’s area of operation clean and clear of any obstacles. Check 
that the photocells' area of operation is free from obstacles • Children must be 
supervised to make sure they do not play with the operator and the fi xed control 
devices or stand in the turnstile's area of operation. Keep any remote control 
devices (i.e. transmitters) or any control devices away from children as well, 
to prevent the operator from being activated accidentally • The operator is not 
designed to be used by persons (including children) whose physical, sensorial 
or mental capacities are limited, or who are lacking in experience or knowledge, 

unless said persons can be supervised or given instructions regarding using the 
operator by a person responsible for their safety • Frequently check the system, 
to see whether any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the cables and any 
accessible connections. Keep any joints lubricated and clean, and do the same 
where friction may occur • Perform functional tests on photocells every six 
months. Ensure that the glass on the photocells is kept clean (use a cloth slightly 
moistened with water; do not use solvents or any other chemicals as these 
could damage the devices) • If the system requires repairs or modifi cations, 
disconnect the power to the operator and do not use it until safety conditions 
have been restored • Cut off  the electrical power supply for manual opening. 
Read the instructions • If the power cable is damaged, it must be replaced 
by the manufacturer or the technical assistance service or by a person with a 
similar qualifi cation so as to prevent any risks • It is STRICTLY FORBIDDEN for 
users to perform OPERATIONS THEY ARE NOT EXPLICITLY REQUIRED AND ASKED 
to do. For repairs, adjustments and extraordinary maintenance, CONTACT THE 
SPECIALIST TECHNICAL SERVICE CENTRE • On the periodic maintenance log, 
note down the checks you have done.

Further special instructions and advice for all

• Avoid working near the turnstiles or moving mechanical parts • Stay clear of 
the turnstile's area of operation when in motion • Do not resist the direction 
of movement of the operator; this may pose a safety hazard • At all times be 
extremely careful about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using a selector or 
command in ‘hold-to-run’ mode, keep checking that there are no people in the 
area of operation of the moving parts. Do this until you release the command 
• The turnstile may move at any time without warning • Always cut the power 
when cleaning or performing maintenance.  

Danger of hand crushing

Danger - live parts

No transit during the manoeuvre

Summary of Contents for TWISTER LIGHT PSBPS07N

Page 1: ...INSTALLATION MANUAL English EN 119G3782EN TRIPOD TURNSTILES TWISTER LIGHT PSBPS07N PSBPS08 PSBPS09 PSBPS10 ...

Page 2: ... identification data must be clearly visible Before connecting the turnstile to the power supply make sure the identification data corresponds to the mains data The turnstile must be connected to an effective compliant earthing system The manufacturer disclaims any liability for the use of non original products this also results in the invalidation of the warranty All hold to run commands must be pl...

Page 3: ...nst climbing over Automatic tripod release in the event of a blackout 001PSBPS10 AISI 304 steel bidirectional electromechanical turnstile with scotch brite finish complete with control board hydraulic damper and LED arrow indicators lights plus arm drop system Automatic tripod release in the event of a blackout Technical data Model PSBPS07N PSBPS08 PSBPS09 PSBPS10 Protection rating IP 44 Control p...

Page 4: ... and washers for fixing the legs 13 Screw for fixing the casing 1 Legs 2 Tripod 3 Steel housing 4 Casing 5 Casing cover 6 Top cover 7 LED arrow indicatorss 8 Mechanism 9 TOR100A control panel 10 Cover lock 11 Screws and washers for fixing the legs 12 Screw for fixing the casing 13 Photocell holder crosspiece 14 Security photocells 15 Protection against climbing over sensors 1 Legs 2 Tripod 3 Sheet...

Page 5: ...time without prior notice by CAME Cancelli Automatici S p a Dimensions Example of a system 1 Tripod turnstile 2 Arrow indicators 3 Junction box 4 Barrier Examples of use Standard installation Wall flanking installation Multiple installation A turnstile regulated exit should not be considered an emergency exit Always provide an exit for emergency situations and for the physically impaired Recommend...

Page 6: ...e table must be re evaluated based on actual power draw and distances When connecting products that are not specified in this manual please refer to the documentation provided with said products Connection Cable type Cable length 1 10 m Cable length 10 20 m Cable length 20 30 m 230 V power supply control panel FROR CEI 20 22 IEC EN 50267 2 1 3G x 1 5 mm 2 3G x 1 5 mm 2 3G x 1 5 mm 2 Accessory powe...

Page 7: ... screws M10x60 and flat head washers Drill the marked holes and insert the dowels into them The floor on which the turnstile is fixed must be perfectly level Securing the turnstile The turnstile ancoring spot depends on the size of the gap and the possible accessories to be connected Once you have determined the location use a pencil to mark the drill holes according to the dimensions indicated mm...

Page 8: ...d L2T Black Replace the 1 6 A line fuse with a 3 15 A unit Must be performed by the installer ELECTRICAL CONNECTIONS Description of the components 1 Transformer 2 Transformer terminal block 3 Accessory fuse 4 Transit sensor terminal block 5 Line fuse 6 Power supply terminal block 7 Control ans safety device terminal block 8 Electric lock terminal block 9 Arrow indicators terminal block PSBPS10 PSB...

Page 9: ...without prior notice by CAME Cancelli Automatici S p a Devices already connected all models White Brown Green Transit sensor White Red 230 V AC White Black 120 V AC Blue Blue Transformer Red Red Red Red Electric lock Photocell Photocell Photocells PSBPS09 PSBPS09 Sensor Sensor Protection against climbing over sensors PSBPS09 PSBPS09 Buzzer PSBPS09 PSBPS09 Devices to be connected Arrow indicatorss ...

Page 10: ...llows clockwise unlocking of tripod The tripod will lock automatically after a fixed time of 10 s Release button N C contact Allows the tripod to be unlocked for rotation in both directions Terminal block for 24 V AC powering of accessories with maximum current and power draw of 250 mA and 35 W respectively FINAL OPERATIONS Wait 10 seconds before performing any operation after connecting the turnst...

Page 11: ... by acting on the tripod and while screwing unscrewing the damper adjust braking force of the rotating mechanism it must smoothly reach the end run during slowdown Make sure that slowdown is as expected for both clockwise and anti clockwise rotation Lock the hydraulic damper by tightening the bolt ADJUSTING THE HYDRAULIC DAMPER Put the cover on and close the lock with the key MAINTENANCE Before an...

Page 12: ...n engaged Invite the person to stop leaning on the arm and try again Contact service Check the validity of the release command The tripod does not slow down at end run The hydraulic damper is not functioning properly Adjust the damper The turnstile is unlocked after passage The transit sensor is incorrectly positioned The transit sensor is damaged Check the position of the transit sensor Contact s...

Reviews: