background image

RBM84 - 

Hardware and connections

5

Pa

g

5

 - 

M

an

u

al

 c

od

e: 

FA

0

0

18

9

M

0

4

FA

0

0

18

9

M

0

4

 ve

r.

 

1

 10

/2

0

1

5

 © C

A

M

E

 s.p.a. - T

h

e d

ata a

n

d i

n

fo

rm

ati

on p

rovi

d

ed

 in

 th

is

 m

an

u

al

 a

re s

u

b

je

ct to c

h

an

g

e at a

ny ti

m

e w

ith

ou

t p

ri

or n

oti

ce

 by C

A

M

E S

.p.a.

Technical data for individual components

RBM84

REM

PC30

WA01

TSP00

S5000

S6000

S7000

PST001

Power supply

120/230V

120/230V

15V AC

120-230V

15V DC

12/24V 

-

10VDC

230V AC

Maximum power

18W

8W

2.7W

2.3W

0.45

1W

-

0.05W

55W

Current draw when idle

40mA

34 mA AC

180mA AC

10mA AC

30mA DC

43mA AC

-

3.2mA

130mA

Protection rating

IP54

IP54

IP20

IP40

IP54

IP54

IP54

IP54

IP44

Working 
temperature

-20 / 55C°

-20 / 55C°

-20 / 55C°

-20 / 55C°

-20 / 55C°

-20 / 55C°

-20 / 55C°

-20 / 55C°

-20 / 55C°

The following features are off ered for all these applications and for any system that includes access and/or exit points that require 
authorisation/control/recording/monitoring:

For the system as a whole

-  Confi guration - within the system - of diff erent control devices, even for the same automation: a keyboard selector, transmitter 

or transponder cards (magnetic or swipe), home control systems (Wave).

-   Automation enabling/disabling.
-   Digital input enabling/disabling.
-   Defi nition of 30 homogeneous groups of users for collective authorisation/denial.
-   Setting of 8 "vacant/occupied" control traffi

  c lights, with maximum number of spots and availability. 

-   Selection of relay operating mode, bistable / monostable (with setting of monostable closing time).
-   Selection of contact type NO/NC, for all digital inputs.
-   Settings for 8 diff erent time brackets of the day.
-   Enabling/disabling of time brackets.
-   Programming of hourly costs for time brackets and whole day.
-   Set of 4 discount levels.
-   Programming complementary parking time limit.
-   Setting the timed AntiPassBack duration.
-   Programmed access opening and closing.
-   Defi nition of "blocked days": partial or total system lock-up
-   System lock-up/release.
-   Storage/recording of 5500 diff erent users with personal data and code of the control device assigned.
-   User list print function.
-   User operations per set time interval display or print function.

For each user

-   Association to a homogeneous group.
-   Enable/disable: edits or deletes user permanently
-   Defi nition of type of access: normal, time or amount prepaid, subscription (in days).
-   Antipassback type selection: normal or timed.
-   Setting of hourly costs for customised credits.
-   Allocation of discounts and complementary parking.
-   Allocation of time brackets on a daily basis.
-   Monitoring the status of the user: if recorded, last entrance and last exit, total stay, total accesses, remaining credit.
-   User confi guration print function.
-   User operations per set time interval display or print function.

All these functions can be activated/blocked/changed at any time through the software, and all drives connected to RBM84 and REM 
can be locked/unlocked using the safety push buttons connected to digital inputs.

What RBM84 can do

Summary of Contents for RBM84-HW

Page 1: ...x 39 0422 4941 www came it info came it Came Cancelli Automatici una societ certi cata ISO 9001 per il sistema di gestione della qualit aziendale e ISO 14001 per il sistema di gestione ambiantale Came...

Page 2: ...RBM84 connection Modem Personal Computer 13 RBM84 connection REM single segments 14 RBM84 connection REM two segments 15 Connection RBM84 REM Sensor remote control 16 Connection RBM84 REM S5000 keybo...

Page 3: ...rd selectors TSP00 sensor for transponder card LT001 reader for magnetic stripe cards WAVE sensors WA01 Twister and Guardian turnstiles The number of these devices varies depending on the type of syst...

Page 4: ...risation entrance exit recording entrance stay exit monitoring entrance and exit activation and selection controlling parking time and costs locking releasing the system and or providing real time aut...

Page 5: ...relay operating mode bistable monostable with setting of monostable closing time Selection of contact type NO NC for all digital inputs Settings for 8 different time brackets of the day Enabling disab...

Page 6: ...s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME S p a Recommended cable unshielded braided multi strand CAT 5 U UTP AWG 24 Types o...

Page 7: ...rol board 2 R700 and R800 board connector 3 Sensor connection terminal 4 LBD2BN1 battery charger board connection terminals 5 Battery connection terminals 6 230V A C line connection 7 Connector termin...

Page 8: ...supply safety fuse 3 Circuit safety fuse 4 Connection terminals for transponder sensors TSP00 and reader for magnetic stripe cards LT001 5 Connectors for signal decoding cards selectors sensors transm...

Page 9: ...terminal block 3 1 6A accessory fuse 4 Limit switch connection terminal block 5 1 6A line fuse 6 Board power supply terminal block 230V A C 7 Control accessories and devices connection terminal block...

Page 10: ...e by CAME S p a Function 11 Stand Alone or OnLine mode In Stand Alone OFF the turnstile works automatically while On Line ON the turnstile is connected and controlled by RBM84 Function 12 Device numbe...

Page 11: ...2 RS232 serial port for PC connection 3 Rbm84 connection terminals RS485 serial port 4 12V A C power supply 5 RS232 cable x 1 5 m complete with connectors 6 S5000 S6000 S7000 selector code memorisati...

Page 12: ...nge at any time without prior notice by CAME S p a RS232 serial port Port COM 1 5 m cable for RS232 serial ports supplied with connectors 12V AC power supply for 230V A C power supply 50 60Hz 800 mA c...

Page 13: ...connected to RBM84 PC for remote control Telephone Line N B It is possible to use standard Hayes GSM or V92 analogue modem with RS232 connection Communication is between a PC its modem the receiving...

Page 14: ...maximum distance must be 1000 m Connecting to A segment RBM84 is at the end of the cable path Each Rem is identi ed by Rbm84 through a progressive sequential numbering 1 to 60 regardless of the posit...

Page 15: ...OUTPUT CAN BE CONNECTED TO TERMINAL BLOCK 1 OR 2 Segment A Two SEGMENT connection RBM84 can be located in any position along the cable route from the rst to the last Rem Turnstile maximum distance mus...

Page 16: ...ct to change at any time without prior notice by CAME S p a On Rem simply connect a AF43S radio frequency card and connect a TOP A433N antenna on the Rem base card Connect the receiver R501N that incl...

Page 17: ...and connections 17 Page 17 17 Manual code FA00189M04 FA00189M04 ver 1 10 2015 CAME s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME...

Page 18: ...code FA00189M04 FA00189M04 ver 1 10 2015 CAME s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME S p a White A Blue B Blue B White A...

Page 19: ...data and information provided in this manual are subject to change at any time without prior notice by CAME S p a TSP00 Transponder card reader TST01 Transponder proximity card Red S1 Black GND Black...

Page 20: ...s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME S p a Black GND Red S1 Black GND Red S1 Maximum distance 50m Maximum distance 50m...

Page 21: ...4 ver 1 10 2015 CAME s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME S p a Capable of connecting alarms magnetic coils locks etc C...

Page 22: ...any time without prior notice by CAME S p a PST001 Twister Turnstile Connection RBM84 REM Turnstile connection Only with RBM84 software version 3 or later PSHPS07 Turnstile Guardian PST001 Twister Tu...

Page 23: ...tion provided in this manual are subject to change at any time without prior notice by CAME S p a 230 VAC power supply Relay contact 230 VAC power supply Relay contact Connection RBM84 REM WAVE connec...

Page 24: ...time without prior notice by CAME S p a Provide a suitable omnipolar circuir breaker with 3 mm maximum distance between contacts to disconnect the power supply 230 VAC Partial traffic lights associat...

Page 25: ...ation connect an LBD BN1 battery recharger board and relative batteries as protection against power disruption For more complex systems with one or more REMs each group should be equipped qith a UPS t...

Page 26: ...EM n 37 REM n 38 REM n 39 REM n 40 REM n 41 REM n 42 REM n 43 REM n 44 REM n 45 REM n 46 REM n 47 REM n 48 REM n 49 REM n 50 REM n 51 REM n 52 REM n 53 REM n 54 REM n 55 REM n 56 REM n 57 REM n 58 REM...

Page 27: ...purchase additional credit to exit Users with negative credit are denied access N B Dip 1 3 4 and 5 are not used leave OFF Dip 2 OFF A user with 0 credit denied access Dip switch RBM84 Function selec...

Page 28: ...reviso Treviso Italy 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English English Manual code FA00189M04 FA00189M04 ver 1 1...

Reviews: