background image

ENGLISH

E N G L I S H

CAME cancelli automatici s.p.a.

 

Via Martiri della Libertà, 15

31030 Dosson di Casier

TREVISO - ITALY

www.came.it - [email protected]

WARNING!

Important instructions for the safety of people: 

READ CAREFULLY!

Foreword

• Use of the products must be restricted to its intended use 
(i.e. that for which it was expressly built for). Any other use is 
to be considered dangerous. Came Cancelli Automatici S.p.A. 
is not liable for any damage resulting from improper, wrongful 
or unreasonable use •  Keep these warnings with the installa-
tion and use manuals issued with the automated system.

Before installing 

(preliminary check: in case of a negative 

outcome, do not proceed before having 

complied with the safety obligations)

• Make sure that the parts you intend to automate are in 
good working order, and that they are  properly balanced 
and  aligned.  Also,  make  sure  that  proper  mechanical  stops 
are already in place • If the operator will be installed at a 
height of less than 2.5 m from the ground or other access 
level, check whether you will need any protections and/or 
warnings • Any gate leaves, fi tted with pedestrian entrances, 
onto which you will install an operator, must have a blocking 
mechanism when the gate is in motion • Make sure that the 
opening of the automated gate is not an entrapment hazard 
as regards any surrounding fi xed parts • Do not mount the 
operator upside down or onto any elements that may fold 
under its weight. If needed, add suitable reinforcements at 
the points where it is secured • Do not install onto gates on 
either an upward or downward slope (i.e. that are not on fl at, 
level ground) • Check that any lawn watering devices will not 
wet the gearmotor from the bottom up.

Installation

• Carefully section off the entire site to prevent unauthorised  
access, especially by minors and children • Be careful when 
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling 
safety equipment • All opening commands (e.g. buttons, key 
selectors, magnetic detectors, etc.) must be installed at least 
1.85 m from the gate’s area of operation perimeter - or where 
they cannot be reached from the outside of the gate. Also, 
the direct commands (e.g. push button, or proximity devices, 
etc.) must be installed at a height of at least 1.5 m and must 
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release 
mechanism • Before delivering to the client, verify that the 
system is EN 12453 (impact test) standard compliant. Make 
sure that the operator has been properly adjusted and that the 
safety and protection devices, as well as the manual release 

are working properly • Where necessary and in plain sight, 
apply the Warning Sings (e.g. gate plate).

Special instructions and 

advice for users

• Keep the gate’s area of operation clean and clear of any 
obstacles. Trim any vegetation that may interfere with the 
photocells • Do not allow children to play with the fi xed com-
mand  devices,  or  in  the  gate’s  area  of  operation.  Keep  any 
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether 
any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the 
cables and any accessible connections. Keep any joints (i.e. 
hinges)  lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on 
photocells and sensitive edges, every six months. Keep glass 
panels constantly clean (use a slightly water-moistened cloth; 
do not use solvents or any other chemical products) • If the 
system requires repairs or modifi cations, release the operator 
and do not use it until safety conditions have been restored 
• Cut off the power supply before releasing the operator for 
manual openings. See instructions • Users are FORBIDDEN 
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN 
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL 
ASSISTANCE STAFF • On the periodic maintenance log, note 
down the checks you have done.

Special instructions and 

advice for all

• Avoid working near the hinges or moving mechanical parts 
• Stay clear of the gate’s area of operation when in motion • 
Do not resist the direction of movement of the gate; this may 
present a safety hazard • At all times be extremely careful 
about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using 
a selector or command in ‘maintained action’ mode, keep 
checking that there are no people in the area of operation of 
the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut 
the power when cleaning performing maintenance. 

EN

Summary of Contents for KRONO KR300

Page 1: ...KRONO SERIES INSTALLATION MANUAL KR300 KR310 KR510 AUTOMATION FOR SWING GATES English EN ...

Page 2: ... placed where the moving gate leaves transit areas and driveways are completely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant Make sure that the operator has been properly adjusted and that the safety and protection devices as well as the manual release a...

Page 3: ...ative transport documents showing the company s written authorisation to accept the returned goods including the quality and quantity of the returned goods The returned goods shall not be accepted by the company unless carried out in the above mentioned manner and especially returned goods shall not be accepted if received at any of the company s premises 8 GUARANTEE The company guarantees the pro...

Page 4: ...ds IMPORTANT INSTALLATION SAFETY INSTRUCTIONS CAUTION IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS 2 2 Application The company CAME cancelli automatici is ISO 9001 2000 quality certified it has also obtained the ISO 14001 environmental safeguarding certification CAME engineers and manufact...

Page 5: ...0W Opening time 90 22s Thrust 400 3000 N Duty Cycle 30 Condenser 8 μF Protection Rating IP54 Weight 10 kg 4 2 Technical features 4 4 Overall dimensions 4 3 Description of parts 1 Gearmotor 2 Tail hooking bracket 3 Tail articulated joint 4 Head bracket 5 Pinion 6 Self locking nut UNI 7474 M8 7 Flexible washer Grower ø12 8 Self locking nut UNI 7474 M12 Motor power supply 230V A C 50 60Hz Max draw 1 ...

Page 6: ...ving parts That measurement C is not greater than the value shown in Tab 3 p 6 In this case you need to work on the pillar until said measurement is obtained Make sure the path of the electrical cables complies with the command and safety instructions That there is a soundly secured to the ground mechanical stop to prevent the gate leaf gearmotor from over extending Make sure that any connections ...

Page 7: ...e to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH 5 4 Standard installation 1 Left hand motor unit 2 Right hand motor unit 3 Control panel 4 Radio reveicer 5 Safety photocell 6 Key operated selector switch 7 Flashing light 8 Receiving antenna 9 Photocell column 10 Radio transmitter 5 5 Installing the operator ...

Page 8: ...he best point to which you will secure the gate bracket secure the bracket to the pillar and make sure the quotas shown in the table below are met Gate leaves up to 3 m KR3 Opening A mm B mm C max mm E mm 90 130 130 60 910 120 130 110 50 910 Gate leaf up to 5 m KR5 Opening A mm B mm C max mm E mm 90 200 200 120 1310 130 200 140 70 1310 Pillar Hinge Gate leaf closed position Assemble and weld the t...

Page 9: ... gate leaf making sure the quotas shown in the table are met Note on non metal gate leaves assemble and weld the two parts of the bracket and secure them with proper screws Tail joint Screw M8 x 35 Insert the bushing lubricated into the pillar bracket s hole The bracket has holes that allow the opening angle to be changed Secure the tail joint to the bracket Secure the tail joint to the bracket Bu...

Page 10: ... ZM3E Control panel Connecting the 230V a c delayed opening gearmotor Connecting the 230V a c delayed closing gearmotor Power supply 230V a c 50 60 Hz 5 7 Outward opening installation Gate leaves up to 3 m KR3 Opening A mm B mm E mm 90 130 130 910 Weld the extra bracket to that of the pillar secure the extra bracket to the pillar making sure the A and B quotas are met as shown in the table Open th...

Page 11: ...e susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Pillar bracket Extra bracket Gate bracket Connect the gearmotors to the panel as shown in the diagram ZA3N ZM3E Control panel Connecting the 230V a c delayed opening gearmotor Connecting the 230V a c delayed closing gearmotor Power supply 230V a c 50 60 Hz ...

Page 12: ...ing closing arc when operator is in motion Do not exercise force against the motion of the operator as this could result in potentially dangerous situations Important safety instructions Danger of crushing hands Danger of crushing feet Danger High voltage No transit during operation Do not allow children to play or loiter within the opening closing arc of the operator Keep remote controls and any ...

Page 13: ...ut off the main power to prevent possible accidents due to gate movement To clean the photocells use a water dampened cloth Do not use solvents or other chemical products which may ruin the devices In the event of any strange vibrations or squeaking lubricate the joints with grease as shown in the diagram Make sure there are no plants within the photocell s beam and that the gate motion is free of...

Page 14: ...____________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ Installer s stamp Operator name Date of job Technician s signature Requester s signature Job performed ______________________________________________________________________________________...

Page 15: ...s signature Job performed _______________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ Installer s stamp Operator name Date of job Technician s signature Requester s signature...

Page 16: ...237 Warszawa Warszawa POLAND 48 22 8365076 48 22 8363296 CAME United Kingdom Ltd CAME United Kingdom Ltd Unit 3 Orchard Business Park Town Street Sandiacre Nottingham Nottingham Ng10 5du UNITED KINGDOM 44 115 9210430 44 115 9210431 S c CAME Romania S r l S c CAME Romania S r l B dul Mihai Eminescu Nr 2 Bloc R2 Scara A Parter Ap 3 Buftea Judet Ilfov Bucarest Bucarest ROMANIA 40 21 3007344 40 21 300...

Reviews: