Photocells
Configure NC contact/s C1 and/or C5, input for safety accessories such as photocells.
C1 reopening while closing.
When the boom is closing, opening the contact causes its movement to invert until fully opened;
If unused, shortcircuit contact 2-C1.
C5 immediate closing.
Closing the boom after a vehicle has passed through the operating area of the safety devices.
If unused, set DIP switch 8 to ON.