Tools and materials
Make sure you have all the tools and materials you will need for installing in total safety and in compliance with applicable regulations. The figure
shows some of the equipment installers will need.
Cable types and minimum thicknesses
INSTALLATION
⚠
The following illustrations are mere examples. Consider that the space available where to fit the barrier and accessories will vary depending
on the area where it is installed. It is up to each installer to select the most suitable solution.
⚠
Warning! Use hoisting equipment to transport and position the barrier.
During the set up and installing stages the barrier could be unstable and tip over. So, be careful to not lean on it until it is completely fastened.
Preparing the fastening plate.
⚠
If the flooring does not allow for a sturdy fastening of the entry unit, you will have to set up a cement slab.
Dig a hole for the foundation frame.
Set up the corrugated tubes needed for making the connections coming out of the junction pit.
The number of tubes depends on the type of system and the accessories you are going to fit.
Types of cable and minimum sizes
Connection
Type of cable
Cable length
1 < 15 m
Cable length
15 < 30 m
Control panel power supply 230 V AC
H05RN-F
3G x 1.5 mm
2
3G x 2.5 mm
2
Photocell transmitters
FROR CEI 20-22
CEI EN
50267-2-1
2 x 0.5 mm
2
Photocell receivers
4 x 0.5 mm
2
Control and safety devices
2 x 0.5 mm
2
Antenna
RG58
max 10 m
Paired or CRP (Came Remote Protocol)
UPT CAT 5
max 1000 m
Metal mass detector
(see product literature)
If cable lengths diff er from those specifi ed in the table, establish the cable cross-sections according to the actual power draw of the connected
devices and in compliance with regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and
distances. When connecting products that are not specifi ed in this manual, please refer to the documentation provided with the products.