CENTRE LINES AND EXTERNAL DIMENSIONS

(

Weight of G12000 barrier structure = 250 Kg / Weight of counterweight plates = 500 Kg  / Weight of G0121 bar = 33 Kg)

TECHNICAL CHARACTERISTIC

GENERAL CHARACTERISTICS

Models:

G12000

Barrier with double, non-reversible 24
V DC gear motor.  Galvanised steel
housing with painted finish.

Accessories supplied:

G0121

- Aluminium barrier bar composed of:
      Ø120 mm tube with L=6200 mm
      Ø100 mm tube with L=6000 mm.
- Hardware and accessories for
mounting the barrier bar.
- Fixed support for the barrier.

Description:

- Motorised barrier for control of
passages with width of up to 12 m.
- Designed and built entirely by
CAME S.p.A., meets UNI 8612 safety
standards, with IP54 degree of
protection.
- Guaranteed 12 months, unless
tampered with.

Optional accessories:

LB35

Circuit card for installation of an
emergency battery.

G0461

Package of red phosphorescent
strips for the barrier bar.

IIIIImportant

:  For easy installation and maintenance, be sure to use CAME original control equipment, safety systems and

accessories.

580

865

645

760

865

235

1230

1000

12000

ø100

ø120

PRODUCT

VERSION

VOLTAGE

REQUIREMENT

CURRENT DRAW

TOTAL MOTOR

POWER RATING

DUTY CYCLE

REDUCTION

RATIO

TORQUE

DURATION OF

OPENING CYCLE

WEIGHT

1.0

230 V A.C.

24 V D.C.

15 A max

300 W

50 %

1/202

600 Nm

10 s

783 kg *

Summary of Contents for G12000 Series

Page 1: ...Documentazione Tecnica 56 rev 2 0 03 2001 CAME CANCELLI AUTOMATICI 119G56 GB SERIE GARD G12000 CANCELLI AUTOMATICI ROAD BARRIER...

Page 2: ...barrier Description Motorised barrier for control of passages with width of up to 12 m Designed and built entirely by CAME S p A meets UNI 8612 safety standards with IP54 degree of protection Guarant...

Page 3: ...rectangular plates which are assembled as needed 5 RELEASE SYSTEM Manual with PVC handle and cord in self lubricating sheath safety lock 6 HOUSING Load bearing structure in steel profiles and externa...

Page 4: ...base is perfectly level and that the electrical cables for the unit protrude in the area indicated b detach the mounting base from the housing and mount the anchor stays on the base apply grease and...

Page 5: ...f the rear tube 100 mm cut the tube to the correct length and install the end cap fixed length 6200 mm depth of insertion b assemble the barrier bar by sliding the rear tube into the front tube 120 mm...

Page 6: ...ing base c position and mount the fixed support for the barrier bar and make sure it is in perfect longitudinal alignment with the housing g check for misalignment and adjust if necessary then firmly...

Page 7: ...the support alternatively on the left and right until the bar shows signs of raising N B if not all the counterweight plates are used they must be fixed with a hose clamp to avoid possible release dur...

Page 8: ...arged automatically refer to instruction sheet Flashing signal light when bar is in motion Plug in radio receiver Other functions available Automatic closing The automatic closing timer is automatical...

Page 9: ...t STOP button N C see selection functions OPEN button N O Connector N O radio and or pushbutton See DIP 2 for command type Button operation closure only Contact N C for re opening during closure if no...

Page 10: ...vated 2 2 3 funcion 24V output during movement and in the closed position ON OFF activated deactivated 3 3 3 function 24V output during movement ON OFF deactivated activated 3 3 9 9 function total sto...

Page 11: ...LACI N TRIMMERS EINTELLUNG TRIMMERS R GLAGE TRIMMERS TRIMMERS ADJUSTMENT REGOLAZIONE TRIMMERS SENS T C A Trimmer SENS Adjustment of amperometric sensitivity min max Trimmer T C A Adjustment automatic...

Page 12: ...first encoding operation must be carried out whilst keeping the jumpers positioned for channels 1 and 2 as per fig A see fig B for any subsequent settings on different channels T262L M T302L M P1 P2...

Page 13: ...1 P2 CH2 P3 CH3 P4 CH4 1 2 3 4 5 6 7 8 9 10 C P1 P2 P3 P4 T432S set the code to dip switch C and channel to D P1 CH1 and P2 CH2 default setting T432M T312M 1 2 3 4 5 6 7 8 9 10 1 2 3 4 C D P1 P2 P2 CH...

Page 14: ...the lights up of LED sign the code stored Fig 2 IMPORTANT Do not store the code on the circuit card unless the barrier is closed N B If you wish to change the code on your transmitters in the future...

Page 15: ...al board for the pilot motor in the normal CONNECTIONS FOR 2 COMBINED MOTORS CONTROLLED TOGETHER ZL37B CONTROL PANEL 1 On one of the two control panels set Dip 7 to ON in order to select the motor con...

Page 16: ...33 01 46130505 33 01 46130500 CAME GMBH________KORNTAL BEI STUTTGART 49 07 11839590 49 07 118395925 CAME GMBH____________SEEFELD BEI BERLIN 49 03 33988390 49 03 339885508 CAME PL SP ZO O_____________...

Page 17: ...Gate automation equipment must be installed in accordance with all current legislation namely Machinery Directive 98 37 EC and BS EN12453 Important Information BRUNDLE...

Reviews: