CAME FROG J Installation Manual Download Page 3

—#

—#

Pa

g.

 

33

  - 

Ma

n

u

al

 c

od

e: 

11

9

A

U

1

4

E

N

11

9

A

U

1

4

E

N

 ve

r.

 

1

  

1  

0

9

/2

0

14  © C

A

M

E c

an

ce

lli

 auto

m

ati

ci

 S

.p.

A

. - 

Th

e d

ata a

n

d i

nf

or

m

ati

on r

ep

orte

d i

n th

is

 in

sta

lla

tio

n m

an

u

al

 a

re s

u

sc

ep

tib

le to c

h

an

g

e at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n C

A

M

E c

an

ce

lli

 auto

m

ati

ci

 S

.p.

A

. to n

otify u

se

rs.

ENGLISH

4.1 Gate Operator

4 Description

2.1 Intended use

1 Legend of symbols

 

This symbol tells you to read the section with particular care.

 

This symbol tells you that the sections concern safety issues.

 

This symbol tells you what to say to the end-users.         

2 Intended use and application

The FROG-J operator is designed to automate swing gates used in residential or condominium settings.

 The use of this product for purposes other than those described above and installation executed in a manner other than                     

as instructed in this technical manual are prohibited.

3 Reference Standards

2.2 Application

This product is engineered and manufactured by CAME cancelli automatici S.p.A. and complies with current safety regulations.
Guaranteed 24 months if not tampered with.
The main component parts of the operator are a foundation casing, a release group, a gearmotor and a transmission arm.
The foundation casing is made of 1.5 mm thick ABS plastic on the sides and of 4mm galvanised steel on the bottom plate. Inside is 
housed the release group with custom key for manually releasing the operator. The gearmotor, is made of cast aluminium in which 
works an irreversible, gear-ratio and, endless screw and helical crown system.

4.2 Technical features

FROG J 

Control board power supply: 230 A.C. 50/60Hz
Motor power supply: 24V D.C. 50/60Hz
Max draw: 10 A 
Nominal voltage: 240W
Max Torque.: 260N
Gear ratio: 1/1396,5
Duty cycle: Intensive use
Protection Rating: IP67
Weight: 6kg
Insulation rating:

The company: CAME Cancelli Automatici S.p.A. is ISO 9001:2000 quality certified; is has also obtained the ISO 14001 environmen-
tal safeguarding certification. Came engineers and manufactures all of its products in Italy.
This product complies with the following standards: EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453.

Max weight of the gate is 200 kg, max width is 1.80 m, and max gate-leaf opening arc is 105°.
With swing gates it is always advisable to install and electro-lock. This is to ensure a reliable closing and to protect the 
gearmotor’s inner workings.

Summary of Contents for FROG J

Page 1: ...INSTALLATION MANUAL FROG J IN GROUND OPERATOR FOR SWING GATES English EN 119AU14EN...

Page 2: ...system conforms to standards EN 12453 and EN12445 impact testing making sure the device has been pro perly adjusted and that the safety and protection and release devices function properly Where neces...

Page 3: ...arts of the operator are a foundation casing a release group a gearmotor and a transmission arm The foundation casing is made of 1 5 mm thick ABS plastic on the sides and of 4mm galvanised steel on th...

Page 4: ...omnipolar cut off device with contacts more than 3 mm apart and independent sectioned off power supply Make sure you have suitable tubing and conduits for the electrical cables to pass through and be...

Page 5: ...he sizes given on the table must be re evaluated based on actual power draw and distances When connecting products that are not specified in this manual please follow the documentation provided with s...

Page 6: ...inside view To facilitate insertion of the in ground casing remove the gate and lower hinges Dig a pit to house the foundation casing set up the shunt boxes and corrugated plastic conduits for connect...

Page 7: ...mission arm with the pin housing ring to the stuffing box anchor them using the M6x16 set screws and nuts Warning the threaded holes for inserting the m10x90 adjustment set screw of the gate pin housi...

Page 8: ...the nut at the opposite end without tightening it completely Insert the gearmotor into the in ground box and anchor it using bolts and washers N B Place the gearmotor s pin housing ring exactly below...

Page 9: ...ps Closing set screw for left gearmotor Procedure for adjusting the opening follow the same steps used in adjusting the closing Note max opening arc of the gate leaf is 105 Before tightening the set s...

Page 10: ...A to notify users ENGLISH After making the necessary adjustments and electrical connections see following chapter place the cover onto the box and screw it down using the supplied cylinder head screw...

Page 11: ...llation manual are susceptible to change at any time and without obligation on CAME cancelli automatici S p A to notify users ENGLISH Re blocking procedure Raise the protective cover of the blocking m...

Page 12: ...y users ENGLISH 6 Connecting to the control panel When making electrical connections use the pit the shunt boxes For further instructions concerning functions and adjustments consult the control panel...

Page 13: ...er s signature Job performed ______________________________________________________________________________________ ____________________________________________________________________________________...

Page 14: ...ask you to keep protecting the environment as CAME deems it to be one of the fundamental points of its market operations strategies by simply following these brief guidelines when disposing DISPOSING...

Page 15: ...AU14EN ver 1 1 09 2014 CAME cancelli automatici S p A The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automa...

Page 16: ...nformaci n sobre la empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da empresa d...

Reviews: