12.6 ELECTRICAL CONNECTION OF OPENING AND SAFETY SENSOR FOR EMERGENCY EXIT 001MR8700
Connect the sensor A side, using the supplied cable to the terminals of the electronic control, as follows:
CB01E
001MR8700 sensor (output=current)
Notes
OPE
N
IN
G
0
Brown
1
Green
R0
White/Black
Remove the jumper
R1
Yellow/Black
Remove the resistor
SAF
ET
Y
0
Blue
1
Pink
8A
Gray
Remove the jumper
41
Red
White
Do not connect
Yellow
Do not connect
Connect the sensor B side, using the supplied cable to the terminals of the electronic control as indicated in Section 12.5. For