background image

SUNCORE

SEEDLING HEATING MAT

USER MANUAL

Summary of Contents for AC-SMA1

Page 1: ...SUNCORE SEEDLING HEATING MAT USER MANUAL ...

Page 2: ......

Page 3: ...roduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA ...

Page 4: ...SUNCORE A5 SUNCORE A7 SUNCORE T3 SUNCORE T5 SUNCORE T7 MODEL AC SMA1 AC SMA3 AC SMA5 AC SMA7 AC SMT3 AC SMT5 AC SMT7 UPC A 819137021167 819137021174 819137021181 819137021198 819137021211 819137021218 819137021235 MANUAL CODE SC2008X1 ...

Page 5: ...ual Index Product Warning Key Features Product Contents Installation Starter Guide Programming Other Settings Other AC Infinity Products Warranty Page 5 Page 6 Page 7 Page 8 Page 9 Page 13 Page 16 Page 28 Page 29 Page 30 ...

Page 6: ...d under Children should be supervised to ensure they do not play with this heating mat This mat s controller has a polarized plug one blade wider than the other and will only fit in your electrical plug one way If the plug doesn t fit flip it and try again If it still doesn t fit contact us or an electrician for assistance DO NOT trim cut or otherwise modify the polarized plug Improper use of this...

Page 7: ... made with nylon fabric and drawstring opening to easily store your seedling mat HEATING FILM Lined with far infrared technology to evenly provide uniform heating distribution throughout your seedling trays WATER RESISTANT MAT IP 67 rated heating pad using multiple layers of PVC matting providing high durability and preventing liquid damage SMART CONTROLLER T series models includes a controller th...

Page 8: ...d in both Series PRODUCT CONTENTS SEEDLING MAT x1 STORAGE MAT COVER x1 PRODUCT MANUAL x1 WALL HANG CONTROLLER x1 WALL HANG WOOD SCREWS x2 SENSOR PROBE x1 WIRE TIE x1 CABLE TIE MOUNT x1 SUNCORE SEEDLING MAT Included in T Series ONLY ...

Page 9: ...at on to the ground Do not allow the mat to overlap on to itself STEP 2 Connect the AC power plug to a power outlet to turn on the seedling mat For T series models please continue to pages 10 to 12 to setting up the controller with the mat ALL MODELS ...

Page 10: ... at the bottom side of the controller STEP 2 Position the corded sensor probe and secure it by using the included zip ties and tie mounts if needed The probe can be placed inside a humidity dome seedling tray to monitor the current levels Do not allow the probe to be submerged in water T SERIES MODELS ...

Page 11: ...N STEP 3 To mount the controller locate a spot free of obstruction Secure the controller using the included mounting screw set STEP 4 On the back end of the controller is an opening to hang the device T SERIES MODELS ...

Page 12: ...TEP 6 To power the seedling mat with the controller plug it into of the two ac outlets located on the controller STEP 5 Lastly to power the controller plug the outlet s power cord into an AC power outlet T SERIES MODELS ...

Page 13: ... seeds require different temperatures to germinate Before you begin refer to your seed package and the table on the seedling mat for recommended temperature settings TEMPERATURE If your seed packet does not specify a temperature keep the temperature between 65 F and 75 F 18 24 C Note Make sure to also keep track of the ambient room temperature along with your local weather this can also affect you...

Page 14: ...eds completely with your grow media Set the optional humidity dome over the tray Place the seed tray on the seedling mat and turn it on to begin heating HUMIDITY Humidity domes and plastic covered pots can be used alongside the seedling mat to introduce moisture which help accelerate plant growth ...

Page 15: ...ur soil and overheat your seedlings roots WATERING Before you use your seedling mat water your seed tray s starter mix pellets which should appear dark brown Dry off any excess water Add small amounts of water whenever the mix pellets appear light brown Once the seeds begin to germinate prop up your greenhouse dome about 1 1 5 inches When half of the tray has germinated seedlings remove the tray f...

Page 16: ...emperature and Humidity 2 UP DOWN BUTTON Adjusts the parameters of the mode that you are in In most modes the up button increases and down button decreases the setting Holding both buttons simultaneously sets the parameters to off PROGRAMMING 4 OUTLET STATUS Displays the outlet controller s power status indicating whether or not electricity is being fed to your device ON will display if your devic...

Page 17: ...ays TO ON or TO OFF countdown to show the amount of time before the timer to on timer to off cycle or schedule modes activates or deactivates the fan TO ON represents the amount of time that is left before your device turns on TO OFF represents the amount of time that is left before your device turns off 11 USER SETTING Displays the value you have set for the current mode that you are in Press the...

Page 18: ...F CYCLE On and Off and SCHEDULE On and Off ON MODE Your device will be on regardless of temperature humidity and time based triggers OFF MODE Your device will be off regardless of temperature humidity and time based triggers Note that you can hold the mode button while in any other mode or settings to quickly jump back to OFF Mode PM OFF ON PM PROGRAMMING ...

Page 19: ...ssing the up or down button sets the low temperature trigger Your device will be turned on if the probe s reading meets or falls below this threshold If the probe s reading rises above this trigger point your device will be turned off This turn off point can be adjusted using the buffer setting as shown on page 26 You may also set this trigger above the high temperature trigger to create a specifi...

Page 20: ...essing the up or down button sets the high humidity trigger Your device will be turned on if the probe s reading meets or exceeds this threshold If the probe s reading falls below this trigger point your device will be turned off This turn off point can be adjusted using the buffer setting as shown on page 26 You may also set this trigger below the low humidity trigger to create a specific range i...

Page 21: ...while the countdown is running will pause it until you return to this mode TIMER TO ON MODE In this mode press the up or down button to set a countdown time During the countdown your device will be set to off Once the countdown ends your device will trigger to turn on The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown is shown on the display in the sect...

Page 22: ...ress the mode button again to set a duration for device to be off The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown before the next on or off phase is shown on the display in the section above the setting Leaving the cycle mode while the countdown is running will pause it until you return to this mode ON PM TO OFF CYCLE OFF TO ON OFF PM CYCLE TO ON ON ...

Page 23: ...n your device will be off Please be sure to set the current clock time under settings The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown before the next on or off phase is shown on the display in the section above the setting Your device will not follow this schedule if you leave this mode If you reenter the schedule mode it will continue to follow the ...

Page 24: ... brightness is 1 The settings 1 2 and 3 are not auto dimming and the display will continuously be shown at that brightness level In A2 the display will be shown at brightness 2 but fall to brightness 1 whenever the controller is not being adjusted after 15 seconds In A3 the display will be shown at brightness 3 but fall to brightness 1 whenever the controller is not being adjusted after 15 seconds...

Page 25: ...st the real humidity reading that the sensor probe is measuring Press the up or down button to increase or decrease the data figure by 1 increments The calibration cycle ranges from 8 to 8 and will be applied to the sensor probe s measurements CLOCK SETTING In this setting adjust the current clock time Press the up or down button to increase or decrease the time Once you cycle through 12 00 each t...

Page 26: ...en the measured temperature rises above the set temperature by the buffer number you have set here PROGRAMMING PM T BUFF BUFFER HUMIDITY SETTING The buffer that used in auto mode humidity trigger can be adjusted to prevent the device from turning on and off too quickly due to variations in the environment For high humidity triggers once your device is on it will only turn off when the measured hum...

Page 27: ... you that a particular function or alarm is being triggered TIMER ALERT This icon will flash when a countdown has completed for TIMER TO ON TIMER TO OFF CYCLE or SCHEDULE Mode DISPLAY LOCK ALERT This icon will display when you lock the controller The icon will flash and beep if you attempt to adjust the controller while it is still locked TIMER TO ...

Page 28: ... be hidden but all programs and settings will continue to run in the background This can be done by first holding the settings button to lock the controller Once locked pressing the setting button will hide and unhide the screen OTHER SETTINGS JUMP TO OFF MODE Holding the mode button for two or more seconds while in any mode or settings will automatically jump to OFF Mode This will not work if the...

Page 29: ...sponse to changing temperatures Carbon Filter The duct carbon filter is designed to eliminate odors and chemicals for grow tents and hydroponic spaces It utilizes premium grade Australian charcoal that features greater absorption power and a longer lifespan Enables maximum airflow pass through as part of an intake or an exhaust system Ducting Tubes The four layer ducting tube is used to direct air...

Page 30: ...pire two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the product in water incorrect Installation such as wrong voltage input and misuse for any reason other than intended purposes AC ...

Page 31: ... part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without specific permission from AC Infinity Inc ...

Page 32: ...www acinfinity com ...