GENERAL INSTALLATION INSTRUCTIONS
⚠
The installation must be done by qualified expert technicians and in full compliance with applicable laws and regulations.
Preliminary checks
⚠
Before beginning, do the following:
•
Provide a suitable single-pole disconnection device, with a maximum of 3 mm between the contacts, to disconnect the
power supply;
•
Prepare suitable piping and ducts for routing the electrical cables, ensuring protection against mechanical damage;
•
Make sure that any connections within the container (made to ensure the continuity of the protection circuit) are
fitted with additional insulation compared to the other internal conductor parts;
•
Make sure the door frame structure is sturdy enough, that the hinges are suitable and that there is no friction between
the moving parts;
•
Make sure there are opening and closing mechanical stops.
Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance
with current standards and regulations. The figure shows some examples of installer’s tools.
Types of cables and minimum thicknesses
Connection
Cable type
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Power supply to board 230 VAC
FROR CEI
20-22
IEC EN
50267-2-1
3G x 1.5 mm
2
3G x 2.5 mm
2
3G x 4 mm
2
Power supply to motor 24 VDC
2 x 1 mm
2
2 x 1.5 mm
2
2 x 2.5 mm
2
Power supply to motor 230 V AC
4 x 1 mm
2
4 x 1.5 mm
2
4 x 2.5 mm
2
Flashing light
2 x 0.5 mm
2
2 x 1 mm
2
2 x 1.5 mm
2
Photocell transmitters
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Photocell receivers
4 x 0.5 mm
2
4 x 0.5 mm
2
4 x 0.5 mm
2
Control and safety devices
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Antenna
RG58
max. 10 m
Encoder
TWISTED
max. 30 m
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of
the connected devices and according to the provisions of regulation CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual
power draw and distances. When connecting products that are not specified in this manual, please refer to the documentation
provided with said products.
Summary of Contents for F4000 Series
Page 61: ...F40230E F4024E F4024EP FA00034 RU RU...
Page 66: ...80 250 270 950 min A Pag 6 6 FA 0 0 0 34 R U FA 0 0 0 34 R U 2 2 08 2015 Came S p A 180 B...
Page 72: ...Pag 12 12 FA 0 0 0 34 R U FA 0 0 0 34 R U 2 2 08 2015 Came S p A...
Page 73: ...Pag 13 13 FA 0 0 0 34 R U FA 0 0 0 34 R U 2 2 08 2015 Came S p A...
Page 74: ...ZM3E W V U E E U V W F40230E Pag 14 14 FA 0 0 0 34 R U FA 0 0 0 34 R U 2 2 08 2015 Came S p A...
Page 77: ...Pag 17 17 FA 0 0 0 34 R U FA 0 0 0 34 R U 2 2 08 2015 Came S p A...