WARNING!

Important instructions for the safety of people: 

READ CAREFULLY!

Foreword

• Use of the products must be restricted to its intended use 
(i.e. that for which it was expressly built for). Any other use is 
to be considered dangerous. Came Cancelli Automatici S.p.A. 
is not liable for any damage resulting from improper, wrongful 
or unreasonable use •  Keep these warnings with the installa-
tion and use manuals issued with the automated system.

Before installing 

(preliminary check: in case of a negative 

outcome, do not proceed before having 

complied with the safety obligations)

• Make sure that the parts you intend to automate are in 
good working order, and that they are  properly balanced 
and  aligned.  Also,  make  sure  that  proper  mechanical  stops 
are already in place • If the operator will be installed at a 
height of less than 2.5 m from the ground or other access 
level, check whether you will need any protections and/or 
warnings • Any gate leaves, fi tted with pedestrian entrances, 
onto which you will install an operator, must have a blocking 
mechanism when the gate is in motion • Make sure that the 
opening of the automated gate is not an entrapment hazard 
as regards any surrounding fi xed parts • Do not mount the 
operator upside down or onto any elements that may fold 
under its weight. If needed, add suitable reinforcements at 
the points where it is secured • Do not install onto gates on 
either an upward or downward slope (i.e. that are not on fl at, 
level ground) • Check that any lawn watering devices will not 
wet the gearmotor from the bottom up.

Installation

• Carefully section off the entire site to prevent unauthorised  
access, especially by minors and children • Be careful when 
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling 
safety equipment • All opening commands (e.g. buttons, key 
selectors, magnetic detectors, etc.) must be installed at least 
1.85 m from the gate’s area of operation perimeter - or where 
they cannot be reached from the outside of the gate. Also, 
the direct commands (e.g. push button, or proximity devices, 
etc.) must be installed at a height of at least 1.5 m and must 
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release 
mechanism • Before delivering to the client, verify that the 
system is EN 12453 (impact test) standard compliant. Make 
sure that the operator has been properly adjusted and that the 
safety and protection devices, as well as the manual release 

are working properly • Where necessary and in plain sight, 
apply the Warning Sings (e.g. gate plate).

Special instructions and 

advice for users

• Keep the gate’s area of operation clean and clear of any 
obstacles. Trim any vegetation that may interfere with the 
photocells • Do not allow children to play with the fi xed com-
mand  devices,  or  in  the  gate’s  area  of  operation.  Keep  any 
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether 
any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the 
cables and any accessible connections. Keep any joints (i.e. 
hinges)  lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on 
photocells and sensitive edges, every six months. Keep glass 
panels constantly clean (use a slightly water-moistened cloth; 
do not use solvents or any other chemical products) • If the 
system requires repairs or modifi cations, release the operator 
and do not use it until safety conditions have been restored 
• Cut off the power supply before releasing the operator for 
manual openings. See instructions • Users are FORBIDDEN 
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN 
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL 
ASSISTANCE STAFF • On the periodic maintenance log, note 
down the checks you have done.

Special instructions and 

advice for all

• Avoid working near the hinges or moving mechanical parts 
• Stay clear of the gate’s area of operation when in motion • 
Do not resist the direction of movement of the gate; this may 
present a safety hazard • At all times be extremely careful 
about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using 
a selector or command in ‘maintained action’ mode, keep 
checking that there are no people in the area of operation of 
the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut 
the power when cleaning performing maintenance. 

EN

Summary of Contents for F1000

Page 1: ...FERNI SERIES INSTALLATION MANUAL F1000 F1100 AUTOMATION FOR SWING GATES English EN 119D69EN...

Page 2: ...laced where the moving gate leaves transit areas and driveways are completely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the clie...

Page 3: ......

Page 4: ...dards 4 2 Technical features Gate leaf width m Gate leaf weight kg 2 00 800 2 50 600 3 00 500 3 50 450 4 00 400 Whenever the shutter is over 2 5 m it needs an electrical lock F1000 F1100 always needs...

Page 5: ...tance B is 300 to 380 mm distance A must be at least 150 mm Before installing do the following Make sure the structure of the gate is sturdy the hinges work and that the is no friction between moving...

Page 6: ...230 V control panel power supply FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 230 V motor power supply 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 Flashing light 2 x 1 5 mm2 2 x...

Page 7: ...ici s p a to notify users ENGLISH Front view 150 mm Insert the gearmotor into the base plate and secure it using the two supplied M8x110 screws and M8 nuts Secure the base plate to the pillar using 8...

Page 8: ...automatici s p a to notify users ENGLISH Insert the straight semi arm into the motor shaft Apply the flared washer the M6x20 screw and lock the semi arm using the two grub screws Join and secure the t...

Page 9: ...tivated and screw the microswitch is activated and screw the screw in the related cam During closure F 1000 only release the door and move it to the desired closing position Turn the lower cam until t...

Page 10: ...device out the reach of children to prevent operator from being activated by accident In the event of anomalous behaviour stop using the operator immediately Danger of crushing hands Danger of cru sh...

Page 11: ...d Before performing any maintenance procedures cut off the main power to prevent possible accidents due to gate movement To clean the photocells use a water dampened cloth Do not use solvents or other...

Page 12: ...___ __________________________________________________________________________________________________ _________________________________________________________________________________________________...

Page 13: ...the following Standards DIRECTIVES 98 37 CE 98 79 CE MACHINERY DIRECTIVE 98 336 CEE 92 31 CEE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 73 23 CEE 93 68 CE LOW VOLTAGE DIRECTIVE 89 106 CEE CONSTRUCTION P...

Page 14: ...510 CAME Americas Automation Llc U S A 11345 NW 122nd St Medley FL 33178 1 305 433 3307 1 305 396 3331 ASIA CAME Asia Pacific 60 Alexandra Terrace 09 09 Block C The ComTech 118 502 Singapore 65 6275 0...

Reviews: