Call Panel connections 

4.5

 

Lock Suppression 

+

_

Lock

Secure

Lock

Relay

 

FIGURE 4-5 - 1N4007 DIODE FITTED AT LOCK 

CAME Entrotec recommend locks with built in 

suppression.  If such a lock is not being used 

it is ESSENTIAL to fit suitable suppression, 

as close to the lock as possible.  This  

prevents back EMF and spikes from 

damaging equipment and causing erratic 

operation. 

 

 

 

WARNING 

Failure to fit adequate suppression may 

invalidate any warranty. 

 

 

SUITABLE SUPPRESSION 

CAME Entrotec supply 1N4007 diodes. 

 

 

 

 

 

 

 

 

5

 

Call Panel connections 

5.1

 

Connections from SLR 

 

 

 

 

 

FIGURE 5-1 

 

 

 

12VDC Connections to Call Panel 

12v, 0v 

 

RS485 Data to Call Panel 

 

FS1-FS4

 - Call Panel Supply 

Fuses (1.25 Amp Fast Acting)

 

 

LOCK1-4

 - Not Used

 

 

DOOR1-4

- Call Panel 

Connections 

Summary of Contents for ENTROTEC PRO-DC4

Page 1: ...PRO DC4 installation SETUP guide Issue 001 December 2022 came com entrotec...

Page 2: ...ng Regulations 18th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY T...

Page 3: ...Exit Switch Connections 7 4 2 Fail Open Lock Connection 7 4 3 Fail Closed Lock Connection 7 4 4 Emergency Door Release 7 4 5 Lock Suppression 8 5 Call Panel connections 8 5 1 Connections from SLR 8 5...

Page 4: ...he specification below shows the minimum cable requirements allow for extra cabling if redundancy is required Connection Cable A Door controller to each call panel 2x Cat5e or Cat6 B Lock Relay to loc...

Page 5: ...Overview 5 2 Overview FIGURE 2 1 Item Connection Detail Power Supply Unit PSU Section 3 Page 6 Secure Lock Relay Section 4 Page 7 Network Switch Section 5 2 Page 9 A B C B A C...

Page 6: ...Point Pre Wired 12V to Internal Devices Backup Battery Connections for Sealed Lead Acid Battery Output Voltage Adjustment SYSTEM VOLTAGE 13 8VDC Always test the output voltage Only adjust if required...

Page 7: ...re switches with fail open locks see section 4 2 4 2 Fail Open Lock Connection Connection for fail open locks power to hold e g magnetic locks FIGURE 4 2 4 3 Fail Closed Lock Connection Connection for...

Page 8: ...ssible This prevents back EMF and spikes from damaging equipment and causing erratic operation WARNING Failure to fit adequate suppression may invalidate any warranty SUITABLE SUPPRESSION CAME Entrote...

Page 9: ...ble Type Detail RS485 from Call Panel Splitter 1x Cat5e or Cat6 1 Pair UTP RS485A RS485B 12VDC from Call Panel Splitter 1 Pair UTP 12v White 2 Pair UTP 0v Black Ethernet to Network Switch 1x Cat5e or...

Page 10: ...RE 6 1 6 2 Secure Lock Relay RS485 Address The Secure Lock Relay has connections for up to 4 doors and must have the RS485 address corresponding to the last 2 digits within the Door No of the associat...

Page 11: ...Device List 11 7 Device List IP Address Block ID SIP ID Type Description 192 168 1 111 1 8001 Call Panel Ashwood Court Front Door...

Page 12: ...rotec PRODCGUIDE0322 2022 EN YOU MAY NOT EVEN PARTIALLY REPRODUCE THIS DOCUMENT THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIORNOTICE BY CAME S...