Cable Specification
4
1
Cable Specification
The cabling system is based on Unshielded Twisted Pair
Category 5e
(Cat5e) or
Category 6
(Cat6). The cable must be
annealed pure copper
, meeting or exceeding the requirements
defined in the standard ANSI/TIA 568 C.2.
Failure to comply with this cable specification may result in erratic operation of equipment.
The specification below shows the minimum cable requirements, allow for extra cabling if
redundancy is required.
Connection
Cable
A
Door controller to each call
panel:
2x Cat5e or Cat6.
B
Lock Relay to locks:
2x 1.5mm² multi-stranded flex or singles (route through
any exit/fire switch or break glass for fail safe operation).
C
Lock Relay to exit switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
D
Lock Relay to fire switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
1.1
Typical Configuration
FIGURE 1-1
�
�
�
NOTE
For setup of the Call Panel refer to the PRO-DP* Installation Guide.