background image

5

ENGLISH

T

h

e d

at

a a

n

d i

n

fo

rm

at

io

n s

h

ow

n i

n

 t

h

is

 d

ia

lo

g

u

e m

ay b

e c

h

an

g

ed by C

am

e C

an

ce

ll

i A

u

to

m

at

ic

i S

.p

.A

. a

t a

n

y t

im

e w

it

h

o

u

t p

ri

o

r w

ar

ning

.

- Dig a pit to the side of the gate (see measurements from diagram). 
Prepare the corrugated tubes you will need when making connections coming from the shunt pit. 
N.B. the number of tubes depends on the type of system and the accessories you will hook up.

 

The following applications are only examples, as the space for installing the ratiomotor and accessories varies according 

to obstructions. It is thus up to the system installer to select the most suitable solution.

Shunt pit

- Prepare a form box that is larger in size than the securing plate and insert it into the pit. The form box should jut 50mm above 
ground level.
Insert an iron grid inside the from box to reinforce the concrete.
Prepare the securing plate, insert the bolts into the holes and lock them using the supplied nuts and washers. Extract the preformed 
brackets using a screw driver or a set of pliers.

5.5 Securing the plate and installing the assembly

MM

MM

MM

MM

MM

- Position the plate on top of the grid. Careful! The tubes need to pass through the apposite holes.
To position the plate in relation to the rack please see the measurements on the diagram.
Fill the form box with cement and wait for at least 24 hours for it to solidify.

MM

MM

MM

H

Conduits for electric 
cables

Summary of Contents for BX-243

Page 1: ...BX SERIES AUTOMATION SYSTEMS FOR SLIDING GATES INSTALLATION MANUAL BX 243 ...

Page 2: ...ons to use This product is engineered and manufactured by CAME CANCELLI AUTOMATICI S p A in compliance with current safety stan dards Guaranteed 24 months if not tampered with The operator is made of a cast aluminium part inside of which operates the irreversible electromechanical gearmotor and an ABS plastic lining which holds the electronic card transformer and battery rack 4 2 Technical feature...

Page 3: ... the castors are in good working order and properly greased The ground rack must be well secured to the ground entirely above the surface and free of any irregularities that may obstruct the gate s movement The upper guide rails must not create any friction Make sure that there is a closing and an opening endstops Make sure that the operator is attached to a solid surface and protected from any im...

Page 4: ...istances When connecting products that are not specified in this manual please follow the documentation provided with said products 5 3 Cable list and minimum thickness Connection Type of cable Length of cable 1 10 m Leng cable 10 20 m Leng cable 20 30 m Control panel power supply 230V FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 2 5 mm2 3G x 4 mm2 Motor power supply 24V 2 x 1 mm2 2 x 1 5 mm2...

Page 5: ...uitable solution Shunt pit Prepare a form box that is larger in size than the securing plate and insert it into the pit The form box should jut 50mm above ground level Insert an iron grid inside the from box to reinforce the concrete Prepare the securing plate insert the bolts into the holes and lock them using the supplied nuts and washers Extract the preformed brackets using a screw driver or a ...

Page 6: ...s completely on the surface Insert the electric cables into the tubes until they exit about 400mm 4 Remove the cover from the gearmotor by loosening the side bolts perforate the cable shafts using a screwdriver or a pair of scissors and position the gearmotor atop the plate Careful The electric cables must pass through the cable shafts cable shafts Lift the gearmotor from the securing plate by abo...

Page 7: ...rack modules use an excess piece of rack and place it under the joining point then block it using two C clamps 3 Note if a rack is already in place then just adjust the pinion to rack distance Completata la regolazione fissare il gruppo con rondelle e dadi Il coperchio va inserito e fissato dopo le regolazioni e settaggi sulla scheda elettronica MM Open and close the gate manually and register the...

Page 8: ...pening microswitch turning the white cam counter clockwise Secure the cam by turning the screw Adjusting the closing endstop with the motor in release mode fully close the gate Activate the closing microswitch turning the red cam counter clockwise Secure the cam by turning the screw 5 6 Manually releasing the gearmotor insert the customised key and turn it couter clockwise Open the trap door and p...

Page 9: ...remote control All connections are protected by quick fuses see table The card handles the following functions Automatic closing after an opening command Warning light pre flashing Obstacle detection when gate is still at any point Constant monitoring of photocell operations Opening closing Opening closing in maintained action mode partial opening total stop After detecting an obstacle the photoce...

Page 10: ...n Green Red Green Opening micro switch COM NC NC COM 1 Power supply terminals 2 Endstop terminals 3 Motor terminals 4 Encoder terminals 5 Accessory fuse 6 Card fuse 7 Button for memorising the radio code 8 Radio code signalling LED indicator 9 230V power signalling LED 10 Control and signalling LED group 11 Function selector DIP switch 12 Socket for connecting the remote control s radiofrequency c...

Page 11: ...l that gate is open turns off when gate is closed Movement flashing light Contact range 24V 25W max Flashes during the gate s opening and closing phases Stop button N C contact Gate stop button Excludes automatic closing For motion to resume press the command button or the remote control button Key selector and or command button N O contact Gate opening and closing command By pressing the button o...

Page 12: ...hase Input for EN 12978 standard compliant safety devices such as photocells If contact is opened while gate is closing the gate inverts its direction partial stop N C contact Input for EN 12978 standard compliant safety devices such as photocells Gate stops if moving and automatically shuts if this functions has been selected Open while closing N C contact partial stop N C contact DIR photocells ...

Page 13: ...el cancello se non utilizzato cortocircuitare il contatto 2 C8 DF with DFI con nections monitor card 0 43 6 6 6 0 43 DF 0 43 6 6 6 0 43 0 43 53 M 48 48 48 At each open close command the card check the photocells efficiency Any problems with the photocells will cause the PROG Led to flash on the electronic card which cancels any commands from the radio transmitter or push button Electrical connecti...

Page 14: ...ment if the force exceeds the set level the system intervenes by inverting the direction of motion SLOW V Sets the gate s final opening closing phase slow down speeds RUN V Sets the gate s opening closing motion speed 072 LIST WARNINGS OF THE COMMAND AND SAFETY DEVICES CONTROL LEDs PROG Red Led Normally off When the transmitter is activating it turns on or flashes PWR Green led Normally on Shows t...

Page 15: ... motor is stopped gate closed or after a total stop command it prevents any movement if safety devices such as photocells detect any obstacles 6 ON Maintained action The gate works by keeping button pressed one 2 3P opening button and one closing button 7 ON Functioning of the photocells safety test Allows the card to check the efficiency of any safety devices i e photocells after every opening or...

Page 16: ...ransmitters FM 26 995 AF130 TFM FM 30 900 AF150 TFM AM 26 995 AF26 TOP AM 30 900 AF30 TOP AM 433 92 AF43S AF43SM TAM TOP AM 433 92 AF43SR ATOMO AM 40 685 AF40 TOUCH AF Card Insert the radio frequency card into the electronic card AFTER DI SCONNECTING THE POWER and disconnecting any batteries N B the electronic card picks up the radiofrequency card on when it is running on power Connect the antenna...

Page 17: ...NA TOP 434NA TOP 432S TOP TOP 302A TOP 304A TOP TOP 432A TOP 434A TAM T432 T434 T438 TAM 432SA TFM T132 T134 T138 T152 T154 T158 CAME CAME CAME S e e i n s t r u c t i o n s o n p a c k a g i n g 4 4 0 43 072 53 4 4 0 43 072 53 PROG Keep pressed the PROG button on the electronic card The LED will flash Press the button of transmitter to me morise The LED will stay on to signal memorisation Intermi...

Page 18: ...to the hinges or other moving mechanical parts Stay out of the opening closing arc when operator is in motion Do not exercise force against the motion of the operator as this could result in potentially dangerous situations Do not allow children to play or loiter within the opening closing arc of the operator Keep remote controls and any other command device out the reach of children to prevent op...

Page 19: ...ells use a water dampened cloth Do not use solvents or other chemical products which may ruin the devices In the event of any strange vibrations or squeaking lubricate the joints with grease as shown in the diagram Make sure there are no plants within the photocell s beam and that the gate motion is free of any obstacles MALFUNCTIONS POSSIBLE CAUSES CHECK AND REMEDIES The gate will not open nor cl...

Page 20: ...ure Job performed______________________________________________________________________________________ ________________________________________________________________________________________________ Installer s stamp Operator name Date of job Technician s signature Requester s signature Job performed_____________________________________________________________________________________ ___________...

Page 21: ...________ Installer s stamp Operator name Date of job Technician s signature Requester s signature Job performed_____________________________________________________________________________________ ________________________________________________________________________________________________ CAME CANCELLI AUTOMATICI S p A employs a UNI EN ISO 14001 certified and compliant environmental protection...

Page 22: ...Free Phone 0508 438 428 Web www gad co nz Email info gad co nz ...

Reviews: