J
7
8
beep
beep
2
3
4
5
6
PROG
PROG
>3’’
>3’’
1
P
age
7
- Manual
FA01031-IT
- 08/2019 - © C
AME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - T
ranslation of the
original instructions
P
age
7
- Manual
FB00865-EN
- 11/2019 - © C
AME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - T
ranslation of the
original instructions
P
age
7
- Manual
FB00865-EN
- 11/2019 - © C
AME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructio
ns
Entry panel brightness level adjustment.
While programming the call keys the entry
panel brightness level can be adjusted from any receiver. Pressing the "Self-connec-
tion" key
on the receiver causes the video camera of the entry panel for which the
brightness level is to be adjusted to be activated. The brightness level can be increased/
decreased by using a previously assigned call key, or by simulating a call from DNA.
First Programming with SEVERAL entry panels
Entering Programming Mode.
Press the PROG key on the power supply
1
until the
PROG LED lights up. If the PROG LED immediately goes out, this indicates a malfunction
in the connections between the power supply and the entry panel. Check the connec-
tions and return to programming. The LEDS on the entry panels light up as shown in
fi gure
2
. Wait 5 seconds for the auto test to be completed and
continue as shown below.
Programming Type of Keys.
Press the fi rst key on the entry
panel
3
until the
LED stops fl ashing along with the back-
lighting LEDs
4
. Repeat this operation for all the entry panels
to be programmed
4
5
: at the end the signals will have this
confi guration
6
.
- Should call keys be present ONLY ON ADDITIONAL BUTTON PANELS, proceed as
shown in the NOTE on page 6.
Programming the call keys.
Press the door release
and AUX2 buttons
7
. On the
entry panel, press the call key to be linked to the receiver
8
: a beep will confi rm that
the setting has been stored. Continue, repeating the same operations for all the other
receivers. The operation can be carried out only from the entry panel with the
LED off
(PE1 in fi g.
6
): to change the entry panel from which to carry out the call programming,
press one of the fi rst 4 positions of the call keys for at least 3 seconds (or press key 1
followed by the
key for entry panels with DNA).
1 P.E
1 P.E
1 P.E
1 P.E
1 P.E
1 P.E
1 P.E
1 P.E
2 P.E
2 P.E
2 P.E
2 P.E
3 P.E
3 P.E
1 P.E
1 P.E
2 P.E
3 P.E
3 P.E
3 P.E
3 P.E
3 P.E
3 P.E
3 P.E
3 P.E