10  - 24803960 15-09-2014 

 

DDI

OFF ON ON ON

Reset

ON ON ON ON

Dip S/W

Feature

S6

D1

Extended ID

D2

Baud rate

D3
D4

S5

D1

Protocol

D2
D3
D4

Baud Rate

S6

D2

D3

D4

2400 bps

OFF

OFF

OFF

4800 bps

OFF

OFF

ON

9600 bps (default)

OFF

ON

OFF

19200 bps

OFF

ON

ON

38400 bps

ON

OFF

OFF

Extended ID

D1

1/99

OFF

1/3999

ON

Video output connection 

RS485 connection

The Dome videocamera is fi tted with a RS-485 receiver that can 
be remotely controlled, via an external control device, for example 
a joystick or a DVR DVR.
RS-485: connect TXA (Tx+) and TXB (Tx-) of the control devices 
RS485 (KBD, DVR…) to TRX+, TRX- of the Dome videocamera.
The RS-485 does not support using a star connection layout. 
For such a connection type, you a serial distributor.The RS-485 
supports a distance of 1.2 km, so for greater distances we suggest 

using repeaters.

Connecting the alarms

From AL1 to 8 (ALARM IN)

To receive and answer from the videocamera about an event, you 
can use magnetic sensors, PIR or others

GND

Connect the ground to the Alarm input and/or the Alarm output 
to the GND connector.

NO/NC (Clean contact relay output)

The video camera may activate external devices, such as buzzers or 
lights via a relay switch. Connect the device to the NO connectors 
(NC) (Alarm Out) and COM (Common). 

Connecting up to the power supply

Connect the 24 VCA 80VA power supply to the Dome videocamera.

Mounting 

Description of parts

  

Hooking slot;

 

  

Left hook;

 

  

Right hook;

 

 

Fastening screw;

 

20 pin connector.

After setting the switches and making the connections as 
explained above, you can mount the videocam. Take the end of 
the Dome videocam with you hand, as illustrated in the drawing.
1. Line up the two yellow stickers and slide the left hook along 
the guide rail until it snaps into place. 
2. Now move the end of the videocam upwards and tilt it until 
the right hook snaps into place. The 20 pin connector will insert 
automatically
3. Immediately fasten the locking screw to the right hook.
You can install the videocamera onto a supporting structure that 
can hold 5 kg of weight.

Dismantling and disposal

Always make sure you comply with local laws before dismantling 
and disposing of the product.
The packaging materials (cardboard, plastic, and so on) should 
be disposed of as solid urban waste, and simply separated from 
other waste for recycling.
Other components may contain pollutants. They must therefore 
be removed and handed over to fi rms authorized to collect and 
dispose of them.

DO NOT DISPOSE OF IN NATURE!

The data and information in this manual may be changed at any 
time and without notice.

Summary of Contents for bpt Brahms XTWV36ST

Page 1: ...XTWV36ST 24803960 Deutsch DE Fran ais FR English EN Italiano IT...

Page 2: ...2 24803960 15 09 2014 A B...

Page 3: ...3 24803960 15 09 2014 C E F D...

Page 4: ...4 24803960 15 09 2014 G I H...

Page 5: ...ettuare l in stallazione conformemente alle istruzioni del produttore e non installare vicino a sorgenti di calore di alcun tipo Nonmodificarelecaratteristichedisicurezzadellaspinapolariz zata Rivolge...

Page 6: ...0 x x OFF ON 19200 x x ON OFF 38400 x x ON ON Terminazione di linea Ogni dispositivo collegato alla fine della linea di comunicazione dati deve terminare con l impostazione dell interruttore DIP op pu...

Page 7: ...NO NC Alarm Out e COM Common Collegamento dell alimentazione Collegare l alimentazione 24VCA 80VA alla telecamera Dome Montaggio Descrizione delle parti Slot di aggancio Gancio sinistro Gancio destro...

Page 8: ...tsources Do not change any of the features of the polarized plug Call qualified skilled staff to perform any maintenance work on the equipment which needs to be fixed any time it is damaged WARNING TH...

Page 9: ...munication linemustterminatebysettingupaDIPswitchor forexample a terminaljumpertopreventpossibleerrorsinthecommandsignal S4 1 2 3 4 Terminated ON x x x Not terminated OFF x x x Pull Up Down x x ON ON...

Page 10: ...layswitch ConnectthedevicetotheNOconnectors NC Alarm Out and COM Common Connecting up to the power supply Connectthe24VCA80VApowersupplytotheDomevideocamera Mounting Description of parts Hooking slot...

Page 11: ...r les fentes de ventilation Effectuer l installation conform ment aux instructions du producteur et l cart de toute source de chaleur Nepasmodifierlescaract ristiquesdes curit delafichepolari s e Pour...

Page 12: ...Web S6 1 2 3 4 4800 x x OFF OFF 9600 x x OFF ON 19200 x x ON OFF 38400 x x ON ON Fin de ligne Toutdispositifconnect lafindelalignedecommunicationdes donn es doit terminer par la configuration de l int...

Page 13: ...lais Connecter le dis positif aux connecteurs NO NF Alarm Out et COM Common Connexion de l alimentation Connecter l alimentation 24VCA 80VA la cam ra D me Montage Description des parties Fente de fixa...

Page 14: ...ngaben des Herstellers vornehmen nicht in der N he von W rmequellen montieren Den gepolten Stecker nicht ver ndern F r Wartungsma nahmen jeder Art Fachmann hinzuziehen Nach jeder Besch digung sind Ein...

Page 15: ...nalfehler zu vermeiden S4 1 2 3 4 abgeschlossen ON x x x Nicht abgeschlossen OFF x x x Pull Up Down x x ON ON Normal x x OFF OFF Max Gesamtl nge des Kommunikationskabels 1 2 km Einstellung im Fall von...

Page 16: ...d COM Gemeinsam anschlie en Stromanschluss Den24VCA80VAStromandieDome berwachungskameraanschlie en Montage Beschreibung der Bestandteile Befestigungshaken linker Haken Rechter Haken Befestigungsschrau...

Reviews: